IN0025 - 6 August 2014
Copyright ©2014 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773
www.lumascape.com.au
Cable entry
4x Through
Holes
5.
6.
IMPORTANT:
Seal cable entry point and 4 small
holes in base with silicone.
Finalise installation and aim as desired. Refer to Surface
Mount Base section for lamping instructions.
7.
Finalise installation and aim as desired. Refer to Surface
Mount Base section for lamping instructions.
NOTE: Use only 1 x circular
cable to keep IP rating
Wiring Diagrams
Low Voltage
Mains Voltage
RGB Remote Driver
Wire Colour Designation
Red
Red +
Orange
Red -
Green
Green +
White
Green -
Blue
Blue +
Black
Blue -
RGB Integral Driver
Wire Colour
Designation
AC
DC
White 1
AC1
+
White 2
AC2
-
Orange
PWM Common
Red
PWM Red
Green
PWM Green
Blue
PWM Blue
Single Colour Dimming
Wire Colour
Designation
AC
DC
White 1
AC1
+
White 2
AC2
-
Orange
PWM +
Red
Green
PWM -
Blue
Single Colour
Wire Colour
Designation
AC
DC
White
AC1 +
Black
AC2 -
Mains Voltage
Wire Colour Designation
Black
Active
Green
Earth
White
Neutral
J
O
I
N
E
Earth lug only required
for mains voltage
Adaptor Base for Signage Continued...