IN0025 - 6 August 2014
Copyright ©2014 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773
www.lumascape.com.au
2.
Use M4 x 10 mm screws to fit base
to bracket.
Secure bracket to pole (6 mm Allen key
required).
3.
Fit grommet assembly (Required for IP rating).
1.
4.
LS6023 - pole clamp accessory
Mark luminaire location on post and drill
clearance hole to suit cable used.
NOTE: Cable exit location is aligned central to
luminaire base.
Minimum pipe size
38 mm
(1.5 in)
PIPE SIZE RANGE
78 mm (3.0 in)
Maximum pipe size
Adaptor Base for Pole
5.
6.
Terminate luminaire. Mains-voltage version
depicted in example. Refer to wiring
diagrams below for details.
Aim luminaire. Refer to Surface Mount Base
section for lamping instructions.
NOTE: Use only 1 x circular
cable to keep IP rating
Wiring Diagrams
Low Voltage
Mains Voltage
RGB Remote Driver
Wire Colour Designation
Red
Red +
Orange
Red -
Green
Green +
White
Green -
Blue
Blue +
Black
Blue -
RGB Integral Driver
Wire Colour
Designation
AC
DC
White 1
AC1
+
White 2
AC2
-
Orange
PWM Common
Red
PWM Red
Green
PWM Green
Blue
PWM Blue
Single Colour Dimming
Wire Colour
Designation
AC
DC
White 1
AC1
+
White 2
AC2
-
Orange
PWM +
Red
Green
PWM -
Blue
Single Colour
Wire Colour
Designation
AC
DC
White
AC1 +
Black
AC2 -
Mains Voltage
Wire Colour Designation
Black
Active
Green
Earth
White
Neutral
J
O
I
N
E
Earth lug only required
for mains voltage