background image

 

 

 

 

 

 

 

 

LumaPro Operating Instructions 

                     33H471 

30W LED Wall Pack 

 

General Safety Information 

 

1. 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

 

2. 

Review the diagrams thoroughly before beginning. If you feel you do not have electrical 
wiring experience, have your fixture installed by a qualified licensed electrician. 

3. 

All electrical connections must be in accordance with local codes, ordinance, and the 
National Electric Code. If you are unfamiliar with methods of installing electrical wiring, 
secure the services of a qualified licensed electrician. 

4. 

Before starting the installation, disconnect the power by turning off the circuit breaker or 
by removing the appropriate fuse at the fuse box. Turning the power off using the light 
switch is not sufficient to prevent electrical shock. 

5. 

Equipment should be mounted in location and at heights where it will not readily be subject 
to tampering by unauthorized personnel. 

6. 

Do not use this equipment for other than intended use. 

7. 

All servicing should be performed by qualified personnel only. 

 

Mounting 

1. 

Drill three mounting holes into mounting surface using a 3/8” drill bit.  Use template to                
locate mounting holes. 

2. 

Use a screwdriver to loosen the (2) screws securing fixture door. Remove fixture rear               
housing from fixture. 

3. 

Use a flat head screw driver to remove appropriate wire way covering from back plate of       
housing. 

4. 

Take care to avoid damaging driver, wires and quick connectors and drill holes through          
castings over fixture mounting holes. 

5. 

Affix fixture to mounting surface by installing anchors (not supplied) through fixture               
mounting holes into holes drilled into the mounting surface. Be sure to use an anchor 
appropriate for the mounting surface in which the fixture is installed.  

6. 

Add 

¼

” bead of exterior grade silicone sealant around the perimeter of the wall pack on  

the wall to inhibit any moisture from attachment screws. 

    

 