3
LumaPro Operating Instructions
33H471
30W LED Wall Pack
General Safety Information
1.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
2.
Review the diagrams thoroughly before beginning. If you feel you do not have electrical
wiring experience, have your fixture installed by a qualified licensed electrician.
3.
All electrical connections must be in accordance with local codes, ordinance, and the
National Electric Code. If you are unfamiliar with methods of installing electrical wiring,
secure the services of a qualified licensed electrician.
4.
Before starting the installation, disconnect the power by turning off the circuit breaker or
by removing the appropriate fuse at the fuse box. Turning the power off using the light
switch is not sufficient to prevent electrical shock.
5.
Equipment should be mounted in location and at heights where it will not readily be subject
to tampering by unauthorized personnel.
6.
Do not use this equipment for other than intended use.
7.
All servicing should be performed by qualified personnel only.
Mounting
1.
Drill three mounting holes into mounting surface using a 3/8” drill bit. Use template to
locate mounting holes.
2.
Use a screwdriver to loosen the (2) screws securing fixture door. Remove fixture rear
housing from fixture.
3.
Use a flat head screw driver to remove appropriate wire way covering from back plate of
housing.
4.
Take care to avoid damaging driver, wires and quick connectors and drill holes through
castings over fixture mounting holes.
5.
Affix fixture to mounting surface by installing anchors (not supplied) through fixture
mounting holes into holes drilled into the mounting surface. Be sure to use an anchor
appropriate for the mounting surface in which the fixture is installed.
6.
Add
¼
” bead of exterior grade silicone sealant around the perimeter of the wall pack on
the wall to inhibit any moisture from attachment screws.