- 11 -
7.6 SHUTDOWN
To stop the engine in an emergency, turn the stop
switch to the OFF position.
Under normal conditions, use the following
procedure:
6-1. Set the speed control lever at the low speed
position and allow the engine to run at low speed
for 2 or 3 minutes before stopping.( Fig-11)
6-2.Tum
the
stop
switch
to
the
OFF
position.(Fig-12)
6-3.Close the fuel cock. (Fig-13)
7.7 SERVICE&STORAGE
CAUTION
Flammable liquid: Stop engine and to not
smoke or allow work in immediate area when
refueling. Fire or explosion could result from
flames or sparks.
Moving parts: Shutdown engine before
performing service or maintenance. Contact with
moving parts can cause serious injury.
High temperature: Allow machine and
engine to cool before performing service or
maintenance. Contact with hot components can
cause serious burn.
7-1. Daily Service
A. Remove mud, dirt, etc, from the unit.
B. Clean bottom face of the vibrating plate.
C. Check the air cleaner element and clean if
necessary.
D. Check all nuts, bolts, and screws for tightness
and re-tighten as necessary.
7-2. Weekly Service
A. AIR CLEANER SERVICE (Fig-14)
Dirty air cleaner element will cause starting
difficulty, power loss, engine malfunctions, and
shorten engine life extremely.
Содержание RP1400 PRO
Страница 2: ......
Страница 4: ......
Страница 20: ...14 REPLACEMENT PARTS LIST 10 1 MAJOR COMPONENTS...
Страница 22: ...16 10 2 VIBRATOR ASSEMBLY...