background image

13 

 

Say Goodbye to Ugly Products 

dust. For a more thorough cleaning, use a diluted vinegar solution to wash 
the pad. If necessary, immerse the pad in the diluted vinegar solution for 
30 seconds to remove hard water buildup. Be sure to rinse the pad 
thoroughly with clear water to remove vinegar residue. 

3.

 

Allow the filter and the cooling pad to air dry completely before replacing 
them in the unit.  

W

ATER 

T

ANK 

C

LEANING

 

The water tank should be emptied regularly to ensure hygienic use. To clean 
the tank, rinse it with warm water and a light detergent solution. Rinse with 
clean water and allow it to dry completely before placing it back into the 
cooler.  

W

ATER 

P

UMP 

M

AINTENANCE

 

Hard water buildup can affect the performance of the cooler’s water pump. To 
prevent malfunctions, clean the pump and internal tubing with a calcium and 
lime cleaning product (such as CLR) at least once a season.  

1.

 

Empty any water from the tank. 

2.

 

Pour the cleaner into the water tank and close it. Be sure to push the tank 
in completely to ensure the water pump is lowered into the tank full of 
cleaner.  

3.

 

With the tank closed, allow the pump to soak for 10 to 20 minutes. 

4.

 

Remove the cooling pad from the back of the unit. 

5.

 

Run the cooler for 30 seconds. This will circulate the cleaning solution 
through the pump and tubing to remove any leftover mineral deposits. Do 
not operate longer than 30 seconds, or damage might occur to other parts 
of the cooler 

6.

 

Rinse the tank and fill it with clean water. Run it for several minutes 
without the cooling pad in place to ensure the cleaning solution has been 
rinsed away. 

7.

 

Replace cooling pad and dust filer and operate unit as normal.  

If the evaporative cooler will not be in use for an extended period of time, place 
the unit back in its original carton and keep it stored in a clean, dry place.  

Содержание EC110S

Страница 1: ...Because you re not like everyone else EVAPORATIVE COOLER EC110S OWNER S MANUAL...

Страница 2: ...any questions or concerns regarding your product or if you would simply like to share an idea with us please feel free to contact us Our friendly and knowledgeable customer support team is here for y...

Страница 3: ...rol 10 Additional Features 11 Maintenance 12 Exterior Cleaning 12 Dust Filter Cooling Pad Cleaning 12 Water Tank Cleaning 13 Water Pump Maintenance 13 Technical Support 14 Product Specifications 14 Tr...

Страница 4: ...e cooler is intended to plug into a matching receptacle Under no circumstances should the plug be altered in any way An improper connection can result in electric shock 8 If possible avoid using exten...

Страница 5: ...ying easy Powerful motor results in more powerful airflow faster evaporation and cooler air Consumes about as much electricity as your typical 100 watt light bulb Eco friendly evaporative cooling syst...

Страница 6: ...l 3 Water level indicator 4 Caster 5 Control panel 6 Remote control storage slot 7 Carrying handles 8 Cooling pad knob 9 Cooling pad slot 10 Dustproof air filter 11 Water tank 12 Power cord bracket 13...

Страница 7: ...detergent FILLING THE WATER TANK 1 Remove the water tank by turning the water tank knob counterclockwise 90 degrees 2 Fill the tank with clean water Pay attention to the water level indicator located...

Страница 8: ...nnect the evaporative cooler to a power outlet The unit will beep twice indicating that the power source is connected The cooler will be in standby mode at this time ON SPEED OFF Buttons Press the ON...

Страница 9: ...not revert back to other speeds if the initial fan speed was set to either 1 or 2 MODE Button The EC110S has 2 different automatic airflow modes Setting the airflow mode is optional Natural Mode Natur...

Страница 10: ...NG THE REMOTE CONTROL The Luma Comfort EC110S is equipped with a remote control A CR2032 3V coin type replacement battery is included for your convenience a To put the battery inside the remote contro...

Страница 11: ...level in the tank drops below the minimum level the unit will produce an audible alert that will last for 10 seconds After 10 seconds the evaporative cooler will automatically turn off If the water ta...

Страница 12: ...benzene etc as these substances can damage the evaporative cooler 2 Thoroughly dry all of the cooler s parts with a soft cloth before reconnecting the unit to the power supply DUST FILTER COOLING PAD...

Страница 13: ...g with a calcium and lime cleaning product such as CLR at least once a season 1 Empty any water from the tank 2 Pour the cleaner into the water tank and close it Be sure to push the tank in completely...

Страница 14: ...etup or operation please contact our product support team at 1 866 737 6390 or support lumacomfort com PRODUCT SPECIFICATIONS Model EC110S Product Dimensions 12 75 x 11 25 x 34 5 Product Weight 16 2 p...

Страница 15: ...e pump is defective a Check the water level in the tank and make sure there is enough water b Press the COOLER HUMIDIFIER button c Contact customer service if there is an issue with the water pump The...

Страница 16: ...of parts that are designed to be replaced such as filters or batteries Power failure and improper power supply such as low voltage defective wiring or inadequate fuses Use of force or damage caused b...

Отзывы: