Operating Manual
Compact Weather Station
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
13
6
Measurement Output
Measurements are transmitted in accordance with UMB binary protocol (Factory Settings).
You can find an example of a measurement request in different protocols and a complete
summary of the list of channels in the Appendix.
6.1
Air and Dewpoint Temperature
Sampling rate
1 minute
Generation of average value
1
– 10 minutes
Units
°C; °F
Request channels:
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float)
min
max
unit
100
120
140
160
Air temperature
-50.0
60.0
°C
105
125
145
165
Air temperature
-58.0
140.0
°F
110
130
150
170
Dewpoint temperature
-50.0
60.0
°C
115
135
155
175
Dewpoint temperature
-58.0
140.0
°F
6.2
Wind Chill Temperature
Sampling rate
1 minute, computed on base of the average temperature
and average wind speed
Units
°C; °F
Request channels:
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float)
min
max
unit
111
Wind chill temperature
-60.0
70.0
°C
116
Wind chill temperature
-76.0
158.0
°F
6.3
Humidity
Sampling rate
1 minute
Generation of average value
1
– 10 minutes
Units
%RH; g/m³; g/kg
Request channels:
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float)
min
max
unit
200
220
240
260
Relative humidity
0.0
100.0
%
205
225
245
265
Absolute humidity
0.0
1000.0
g/m³
210
230
250
270
Mixing ratio
0.0
1000.0
g/kg
6.4
Air Pressure
Sampling rate
1 minute
Generation of average value
1
– 10 minutes
Unit
hPa
Request channels:
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float)
min
max
unit
300
320
340
360
Absolute air pressure
300
1200
hPa
305
325
345
365
Relative air pressure
300
1200
hPa
Note:
For the correct calculation of relative air pressure, the altitude of the location must be
entered in the device configuration (see Figure 11 on page 28). The factory setting for