Commissioning
After the equipment has been installed and connected correctly, the sensor begins
autonomously to take measurements. A Windows
®
PC with serial interface, UMB-Config-
Tool software and interface cable (SUB-D 9 pole; jack - socket; 1:1) are required for
configuration and test purposes.
Attention must be paid to the following points:
Check for correct equipment operation on site by carrying out a measurement request with
the aid of the UMB-Config-Tool (see page 36).
Configure the local altitude in order to ensure the correct calculation of relative air
pressure (see page 32).
The device must be aligned to the North in order to ensure correct wind measurement
(see page 23), or the automatic compass correction must be activated (see page 32).
In order to get correct compass headings the local declination must be configured (see
page 18and 32).
If several Smart Weather Sensors are operated on a UMB network, a unique device ID
must be assigned to each device (see page 31).
There is no protective cover to remove on the sensor itself.