IRS31Pro-UMB
Operating Manual V10 / 01.2020
G. Lufft Mess- und Regeltechnik GmbH
27
(Factory setting: 6)
Swap channel assignment of external
temperature sensors:
This option is used to swap the assignment of the external
temperature sensors.
IRS31 compatibility mode:
switches the Sensor into compatibility mode to IRS31-UMB.
The setting compatibility mode to IRS31-UMB changes the
class ID of the sensor to the class ID of an IRS31-UMB.In
the IRS31-UMB compatibility mode the sensor possesses
an IRS31-UMB compatible channel list and road condition
coding. See chapter 11
Freezing temperature correction factor:
This factor influences the calculation of the freezing
temperature. (Factory setting: 1)
A factor between 0 and 1 increases the freezing
temperature.
A factor greater than 1 reduces the freezing temperature.
Example:
Measured freezing temperature -7°C
Factor 0.5: Freezing temperature -2.69°C
This influence of this factor on the calculation of the freezing
temperature is non-linear.
Freezing temperature mode:
Determines how the freezing temperature is output when
the road temperature is above the temperature limit for
freezing temperature calculations or the water film height is
below the dry threshold.
This setting does not apply to IRS31 compatibility mode.
The output of the freezing temperatures in compatibility
mode is compatible with firmware version 5.2 of the IRS31-
UMB.
0: the freezing temperature is transmitted as long as water
film height is above the dry threshold, otherwise the freezing
temperature of -0.1 ° C is reported.
1: the freezing temperature is transmitted as long as the
sensor can measure it (also below the dry threshold),
otherwise the freezing temperature of -0.1 ° C is reported.
2: the freezing temperature is transmitted as long as water
film height is above the dry threshold, otherwise the error
value 55h(85d) is reported. When the temperature is above
the temperature limit for freezing temperature calculations
the error value 55h(85d) also is reported.
This error message means that the sensor is unable to
measure due to ambient conditions.