The range is -99 to +99. After setting any calibration constant, the “SF”
command must be sent to save the values into flash.
Read LLD – RLn
Reads the lower level discriminator setpoint and readback value from the
specified channel. The return format is “LDnnnnnnnn.” The first four
characters are the setpoint; the last four characters are the readback voltage.
Set LLD – SLnxxxx
Sets the lower level discriminator setpoint for the specified channel. The
value must be formatted to four digits and is adjustable from 0000 to 3300.
Read LLD Actual Cal - RLCnxxx
Reads the lower level discriminator actual calibration constant for the
specified channel. The return format is “±n.n.”
Set LLD Actual Cal – SLCnxxx
Sets the lower level discriminator actual calibration constant for the specified
channel. The value must be formatted as “±nn.” Do not include the decimal
place. The range is -99 to +99. After setting any calibration constant, the
“SF” command must be sent to save the values into flash.
Read ULD – RUn
Reads the upper level discriminator setpoint and readback value from the
specified channel.The return format is “UDnnnnnnnn.” The first four
characters are the setpoint; the last four characters are the readback voltage.
Set ULD – SUnxxxx
Sets the upper level discriminator setpoint for the specified channel. The
value must be formatted to four digits and is adjustable from 0000 to 3300.
Read ULD Actual Cal – RUCnxxx
Reads the upper level discriminator, actual calibration constant for the
specified channel. The return format is “±n.n.”
Set ULD Actual Cal – SUCnxxx
Sets the upper level discriminator, actual calibration constant for the
specified channel. The value must be formatted as “±nn.” Do not include
the decimal place. The range is -99 to +99. After setting any calibration
constant, the “SF” command must be sent to save the values into flash.
Содержание 4404-16-4
Страница 3: ......
Страница 17: ...Model4404 16Geo ExplorationSystem TechnicalManual Section2 Ludlum Measurements Inc Page 10 April 2018 ...
Страница 31: ...Model4404 16Geo ExplorationSystem TechnicalManual Section3 Ludlum Measurements Inc Page 24 April 2018 ...
Страница 39: ...Model4404 16Geo ExplorationSystem TechnicalManual Section3 Ludlum Measurements Inc Page 32 April 2018 ...
Страница 44: ...Model4404 16Geo ExplorationSystem TechnicalManual Section6 Ludlum Measurements Inc Page 37 April 2018 ...
Страница 45: ...Model4404 16Geo ExplorationSystem TechnicalManual Section6 Ludlum Measurements Inc Page 38 April 2018 ...
Страница 46: ...Model4404 16Geo ExplorationSystem TechnicalManual Section6 Ludlum Measurements Inc Page 39 April 2018 ...
Страница 47: ...Model4404 16Geo ExplorationSystem TechnicalManual Section6 Ludlum Measurements Inc Page 40 April 2018 ...
Страница 48: ...Model4404 16Geo ExplorationSystem TechnicalManual Section6 Ludlum Measurements Inc Page 41 April 2018 ...
Страница 49: ...Model4404 16Geo ExplorationSystem TechnicalManual Section6 Ludlum Measurements Inc Page 42 April 2018 ...
Страница 50: ...Model4404 16Geo ExplorationSystem TechnicalManual Section6 Ludlum Measurements Inc Page 43 April 2018 ...
Страница 51: ...Model4404 16Geo ExplorationSystem TechnicalManual Section6 Ludlum Measurements Inc Page 44 April 2018 ...
Страница 52: ...Model4404 16Geo ExplorationSystem TechnicalManual Section6 Ludlum Measurements Inc Page 45 April 2018 ...
Страница 53: ...Model4404 16Geo ExplorationSystem TechnicalManual Section6 Ludlum Measurements Inc Page 46 April 2018 ...
Страница 54: ...Model4404 16Geo ExplorationSystem TechnicalManual Section6 Ludlum Measurements Inc Page 47 April 2018 ...
Страница 55: ...Model4404 16Geo ExplorationSystem TechnicalManual Section6 Ludlum Measurements Inc Page 48 April 2018 ...