background image

Page 2 of 10

Digital Audio Distribution Products

U S E R ’ S   G U I D E S    

AESx4  

  SPDIFx7  

  CLKx6  

  GENx6  

  GENx6-96

What’s Included in the Box

The Lucid Hardware Product 

A PS-3, PS-3E, or PS-3J power 

supply

 This User’s Guide

Getting Help

 If you have questions beyond the scope 
of the guide we offer two suggestions:
1) Visit the Lucid web site at 
www.lucidaudio.com. The site hosts a 
forum called LUC (Lucid User’s Confer-
ence) where you can browse or join dis-
cussions among Lucid user’s and Lucid 
technical support personnel.
2) Contact our Technical Services Group 
directly in the following ways:

Tel (425) 

7

78-7728

8:

0

0 am to 

4

:30 pm

Monday through Friday, 

Pacific Time

Fax

(425) 7

78-7727

Email [email protected]
Web

www.lucidaudio.com

Notational Conventions in 

this Quick Start Guide

NOTE   Identifies information that needs 
extra emphasis. Generally supplies 
extra information to help you to better 
use the Lucid product.
CAUTION

   

Identifies information that, if 

ignored, may cause damage to the 
Lucid product or other equipment in your 
system.
WARNING 

  

Identifies information that, if 

ignored, may be hazardous to your 
health or that of others.
CAPS   Controls, switches or other 
markings on the chassis of the Lucid 
product.

Operator Safety Instructions

•  Read these instructions
•  Keep these instructions
•  Heed all warnings
•  Follow all instructions
•  Clean only with dry cloth
•  Use only accessories and attach-

ments specified by the manufac-
turer.

•  Unplug this apparatus during light-

ning storms or when unused for 
long periods of time.

•  This apparatus shall not be 

exposed to dripping or splashing 
and objects filled with liquids, such 
as vases, shall not be placed on the 
apparatus.

Power Source.

  This product is 

intended to operate from a Lucid PS-3, 
PS-3E, or PS-3J power supply only.

Grounding.

  The chassis of this product 

is grounded through the grounding con-
ductor of the PS-3, PS-3E, or PS-3J 
power cord. To avoid electric shock, plug 
the power cord into a properly wired 
receptacle before making any connec-
tions to the product. A protective ground 
connection, by way of the grounding 
conductor in the power cord, is essential 
for safe operation. Do not defeat the 
safety purpose of the grounding plug. 
The three-pronged grounded plug is pro-
vided for your safety. When the provided 
plug does not fit your outlet, consult an 
electrician for replacement of the obso-
lete outlet.

Danger from Loss of Ground.

  If the 

protective ground connection is lost, all 
accessible conductive parts, including 
knobs and controls that may appear to 
be insulated, can render an electric 
shock.

Proper Power Cord. 

 Use only the 

power cord and connector specified for 
the product and your operating locale. 
Use only a cord that is in good condition. 
Protect the power cord from being 

walked on or pinched, particularly at the 
plug, convenience receptacle, and the 
point where the cord exits from the 
apparatus.

Operating Location.

  Do not operate 

this equipment under any of the follow-
ing conditions:  explosive atmospheres, 
in wet locations, in inclement weather, 
improper or unknown AC mains voltage, 
or if improperly fused. Do not install near 
any heat source such as radiators, heat 
registers, stoves, or other apparatus 
(including amplifiers) that produce heat. 
Unplug this device during lightning 
storms or when unused for long periods 
of time.

Stay Out of the Box.

  To avoid personal 

injury, do not remove the product covers 
or panels. Do not operate the product 
without the covers and panels properly 
installed. Only use accessories specified 
by the manufacturer. Clean only with a 
dry cloth.

User-Serviceable Parts.

  There are no 

user serviceable parts inside any of 
these Lucid products. In case of failure, 
refer all servicing to the factory. Servic-
ing is required when the product has 
been damaged in any way, such as 
when a power supply cord or plug is 
damaged, liquid has been spilled or 
objects have fallen into the apparatus, 
the apparatus has been exposed to rain 
or moisture, does not operate normally, 
or has been dropped.

CAUTION 
To prevent electric shock, do not use 
the polarized plug supplied with the 
unit with any extension cord, recepta-
cle, or other outlet unless the prongs 
can be fully inserted.

Содержание AESx4

Страница 1: ...torial errors or omissions contained herein nor is it liable for incidental or consequential damages resulting from the furnishing performance or use of this material Mention of third party products i...

Страница 2: ...connec tions to the product A protective ground connection by way of the grounding conductor in the power cord is essential for safe operation Do not defeat the safety purpose of the grounding plug Th...

Страница 3: ...present Connectors WORD CLOCK Input Is a coaxial BNC connector with nominal input impedance of 75 Ohms Internal termination is provided with a jumper AES Input Is a 3 pin XLR connector with nominal i...

Страница 4: ...cepts S PDIF formatted elec trical signals with nominal impedances of 75 Ohms The S PDIF INPUT provides internal termination of this signal as per the S PDIF IEC958 spec POWER Supplied by external Luc...

Страница 5: ...ere is a lock on the AES input In word clock mode the signal present detector is driven when there is activity on the WORD CLOCK input POWER LED indicates AC power is present Connectors WORD SUPER CLO...

Страница 6: ...NC female con nector with nominal input impedance of 75 Ohms Internal ter mination is provided with a jumper AES INPUT is a 3 pin XLR connector with nominal input imped ance of 110 Ohms Internal termi...

Страница 7: ...0 Ohms Internal termination is provided as per the AES3 spec The data can be either AES3 or AES11 AES3 with no audio data POWER Supplied by external Lucid PS 3 PS 3E or PS3 J power supply WORD SUPER C...

Страница 8: ...OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED ARISING BY LAW OR OTHERWISE INCLUDING WITHOUT LIMITATION ANY OBLI GATIONS OF THE SELLER WITH RESPECT TO CONSE QUENTIAL DAMAGES INCLUDING THE WARRANTIES OF ME...

Страница 9: ...Warranty Repairs If the warranty period has passed you ll be billed for all neces sary parts labor packaging materials and freight charges To Get Your Lucid Unit Repaired USA Customers Only 1 Call our...

Страница 10: ...6 GENx6 96 are in conformity with the standard EN 55103 2 Electromagnetic compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for profession...

Отзывы: