300 SERIES 

ADJUSTABLE BASE

OWNER'S MANUAL

05

04

Safety & Warranty Warnings

PLEASE READ ALL INFORMATION CAREFULLY BEFORE 

USING THIS PRODUCT. SAVE THESE INSTRUCTIONS.

IMPORTANT:

WARRANTY WARNINGS

Do not open or tamper with control box, 
motors, or remote (with the exception of 
battery compartments). The warranty will 
be void if the internal workings of these 
components are tampered with.

SAFETY WARNINGS

•  Do not use bed outdoors.
•  Using bed with oxygen administering 

equipment other than the nasal masked 
type creates a possible fire hazard.

•  When using nasal or masked type 

administering equipment, route and 
secure oxygen or air tubing properly to 
ensure that tubing does not become 
entangled or damaged during normal 
operation of the bed.

•  Keep moving parts free of obstruction 

during bed operation (including sheets, 
clothing, tubing, wiring, and products 
using electric power cords).

WEIGHT LIMITS

•  This product is not rated to support 

weights in excess of: 
 
750 lbs (340 kgs)

•  This limit is inclusive of the mattress and 

bedding. The bed will structurally sup-
port this weight, provided it is evenly 
distributed across the foundation. The 
power foundation is not designed to 
support or lift this amount in the head 
or foot sections alone. Exceeding this 
weight restriction could damge the bed 
and/or cause injury and will void the 
warranty.

 

 

HOSPITAL USE DISCLAIMER

This power foundation is designed for 
residential use only. It is not approved for 
hospital use and does not comply with 
hospital standards.

PRODUCT RATING

The motors are not designed to operate 
continuously for more than (2) minutes in 
an (18) minute time period. Attempting 
to exceed this rating will shorten the life 
expectancy of the foundation and will void 
the warranty.

SAFE OPERATION

•  Use caution when having liquids in or 

around the bed to ensure no spilling 
occurs. In case of spillage, stand in a 
dry, clean area of the floor and unplug 
the bed immediately. Clean up spill and 
allow the area around bed to dry 
thoroughly before using the electric 
controls again. Do not eat or drink hot 
liquids while operating the bed.

•  Do not allow children or individuals with 

disabilities to operate the bed without 
adult supervision.

•  Do not allow any person or pet under 

the bed at any time.

•  During bed operation, make sure body 

is positioned within the confines of the 
bed. Do not place extremities over the 
sides of the bed when operating bed 
functions.

•  After power foundation assembly is 

completed, operate remote control to 
ensure proper functions.

•  Distribute body weight evenly over bed 

surface. Do not place entire weight on 
head or foot sections of the bed, during 
reposition and entering or exiting bed.

FCC COMPLIANCE

•  Operates on 2.4 GHz frequency 

transmitter

•  This device complies with Part 15 of the 

FCC Rules. Operation is subject to the 
following two conditions: (1) This device 
may not cause harmful interference, and 
(2) this device must accept any interfer-
ence received, including interference 
that may cause undesired operation.

•  To comply with FCC RF exposure 

requirements, no change to the antenna 
or the device is permitted. Any change 
to the antenna or the device could 
result in the device exceeding the RF 
exposure requirement and void user's 
right to operate the device.

Содержание ADJUSTABLE BASE L300

Страница 1: ...300 SERIES ADJUSTABLE BASE info lucidmattress com 888 975 8243 SERIAL NO OWNER S MANUAL 300 SERIES ADJUSTABLE BASE TWIN XL...

Страница 2: ...CONTENTS Safety Warranty Warnings Overview Parts List Assembly Remote Control Pairing Synchronizing Two Bases Troubleshooting Warranty 04 06 08 12 16 17 18 300 SERIES ADJUSTABLE BASE...

Страница 3: ...tors are not designed to operate continuously for more than 2 minutes in an 18 minute time period Attempting to exceed this rating will shorten the life expectancy of the foundation and will void the...

Страница 4: ...omponents as explained here If any parts or components are missing or are different than shown in the adjacent image do not attempt to complete the assembly process and contact customer support by cal...

Страница 5: ...r leg for user preference STEP 2 Open the accessories box and ensure all accessories are included see pages 6 7 STEP 1 Remove folded bed base from the box and carefully unfold the base Set it mattress...

Страница 6: ...re the right side Light pressure will be necessary The assembly is now complete Plug the power cord into the wall outlet and refer to pages 12 16 to set program mable positions pair the remote and tes...

Страница 7: ...eries included inserted in the back panel HEAD arrows raise and lower the head section of the base To store current position in memory press and hold the FLAT button and the MEMORY button simultaneous...

Страница 8: ...3 TO PAIR REMOTE Press and hold the HEAD CONTROL RAISE and FOOT CONTROL RAISE buttons simultaneously Then ALSO press and hold the blue button on the control box cord until you hear 2 beeps The remote...

Страница 9: ...eighteen 18 minute period Wireless remote may be experiencing common radio frequency interference from other radio transmitting devices Wait several seconds and try pressing appropriate button again S...

Страница 10: ...aser and Lucid will pay all authorized labor and transpor tation costs associated with the repair or replace ment of any parts YEARS 4 10 During the years four 4 through ten 10 from the date of purcha...