255-700-019
5-17
PacketStar
™
PSAX 20 Access Concentrator User Guide
, Issue 1
Release 6.3.0
Chapter 5 Using System Diagnostics
Operations and Maintenance (OAM)
Display Fields
The display fields on this window provide the following information about all
the circuit emulation-to-ATM VCC PVC connections in the Access
Concentrator system:
3
Select the
Add a Connection
command and press Enter.
The Circuit Emulation-to-ATM VCC PVC Connection Window is displayed
(see Figure 5-11).
Display Field
Description
• Circuit Emulation Side
This column displays the information for
all circuit emulation sides of the connec-
tions. The connection entries are dis-
played in ascending numerical order by
slot, then by port and channel.
• ATM Interface Side
This column displays the information for
all ATM interface sides of the connections.
The connection entries are displayed in
ascending numerical order by slot, then by
port, channel, VPI, and VCI.
• Flow
This column displays the direction of the
data traffic flow for the connections.
• Total:
0/0
The first number in this field indicates the
number of the connection table entry on
the first line of the currently displayed
window. The second number indicates
the total number of connection table
entries for this connection type.