background image

Octel 50 Configuration Note (77007)

 

 

Lucent Merlin Magix 

C o n f i d e n t i a l  

P a g e  

10 

The above information is provided by Lucent Technologies CAG as a guide. 

  See disclaimer on page 1 

Lucent Technologies 

Communications 
Applications Group 

 

Location of Mailbox Number for Go to Voice Mail 

 

 

Code for Immediate Subscriber Login to Mailbox 

#00# 

Start at End of String for Immediate Login 

Disabled

 

Location of Mailbox Number for Immediate Login 

 

 

Start at End of String for Default Code 

Enabled 

Location of Mailbox Number for Default Code 

Note -- Code for Go to Voice Mail  - The Lucent Merlin Magix will 

send either a #02# or a #03# for a code to go to Voice Mail 
depending on whether a call is internal or external.  We chose 
to use one of these codes (the #03#) as the Code to go to Voice 
Mail and use the Default code, in system setup, to send calls to 
Voice Mail when the other code (#02#) is received. 

Note:  Verify all these dialing sequences for your switch 

7.0 

CONSIDERATIONS / ALTERNATIVES 

The following items should be considered, below: 

q

 

Transfers 

q

 

Disconnect Types 

q

 

Line/Pool Considerations 

q

 

Intercom Paging 

q

 

Calling Group Log Out 

q

 

Trunk to Trunk Transfers 

7.1 

TRANSFERS 

Internal calls transferred by Octel 50 do not follow a coverage path, they will 
forward to the console after the number of rings designated in the Transfer 
Release parameter. If this parameter is not set, internal transfers will ring no 
answer. 

If the Octel 50 is programmed to execute a supervised transfer, Handsfree 
Announce must be disabled.  If call forwarding is on at the station, ensure that 
it is for Ring/No Answer only, and that the ring timer is greater than the 
Maximum Rings for the mailbox. 

7.2 

DISCONNECT TYPES 

The Lucent Merlin Magix does not provide consistent disconnect signaling.  
Therefore, it may be necessary for the Voice Mail system to disconnect on 
silence.  Caller prompting and subscriber training are recommended to 
encourage both callers and subscribers to exit the system completely when 
finished. 

Important notes concerning this 

integration 

Содержание Merlin Magix

Страница 1: ... g i n g S e r v e r Configuration Note 77007 Lucent Merlin Magix Revised 1 26 00 Telephone Desktop Computer With Dialogic Analog Board s Central Office Analog Lines Trunks Merlin Magix 1 0 METHOD OF INTEGRATION Integration is achieved by Inband signaling Call forward to personal greeting is achieved via DTMF signals passed from the Lucent Merlin Magix to Octel 50 Message waiting indicators are se...

Страница 2: ...p ring functionality with 4 touch tone receivers 491D1 Power Supply Module Equipped with optional 129B Frequency Generator 30 Hz or Equipped with optional 129C Frequency Generator 25 Hz Note A TTR is needed by an analog port whenever DTMFs are being processed The number of TTRs is dependent on the number of analog ports and the loading of those ports A good estimation is 0 75 TTRs per port for a m...

Страница 3: ... Ver 1 5 and up Forward to Busy Greeting System Forward to Personal Greeting ü Intercom CO Forwarding Station Forward to Personal Greeting Message Waiting Flexible Forwarding NA with CO LCD Display Record Telephone Conversation2 ü LED ü 1 See Section 7 4 Lamp 2 See Section 6 5 Audible Stutter Dial Tone 4 1 DISCONNECT TYPE Disconnect supervision is indicated by the Merlin Magix returning internal d...

Страница 4: ...imum of 20 members An extension may be a member of only one Calling Group 5 1 DEFAULT NUMBERING SCHEME The following figure is a 2 digit map of the factory settings in gray spaces 1 LDN QCC Queue 2 Remote Access Extensions can be renumbered to any number shown in the white spaces 5 2 LUCENT MERLIN MAGIX SYSTEM PROGRAMMING Refer to the Programming section in the Lucent Merlin Magix manual for infor...

Страница 5: ...s of Service The default value for Transfer Return is 4 To modify this parameter erase the current setting using the Drop key Enter the desired value and press Enter From the VMS AA screen select TT Duration This parameter should be set to 75 milliseconds If it is not erase the current setting using the Drop key and enter 75 Press Enter to save your entry From the VMS AA screen select TT Interval ...

Страница 6: ...ing group At Enter Group Members Prompt Specify first Octel 50 port extension number If extension numbers are sequential press the next key to add next Octel 50 port If ports are not sequential press enter to add next extension number Repeat until all Octel 50 ports have been added Select Exit 5 5 SETUP GROUP TYPE FOR OCTEL 50 CALLING GROUP Magix s Mode All Factory Setting Automatic Log Out Return...

Страница 7: ...etting 3 Rings Select Extensions Press More to display second page Select Cover Delay Select Group Select Dial Sender s Extension Press Enter to continue Select Number of Rings 1 9 4 Press Enter to Save To assign trunks to ring directly to Octel 50 Select Extensions Press More to display second page Select Group Calling Select Line Pool See Note Section 7 3 Enter Octel 50 calling group extension n...

Страница 8: ... have been changed NEXT Set the ARS Restriction to allow outdialing Magix s Mode Hybrid PBX only Factory Setting Restricted for Integrated VoiceMail ports ASSIGNING ARS RESTRICTION LEVEL FOR OCTEL 50 EXTENSION Select System Programming Select Extensions Select ARS Restrict Enter the first Octel 50 port to be used for outdialing Select Enter The current ARS Restriction level will be displayed The r...

Страница 9: ...st to match site requirements 6 1 OCTEL 50 Outside Line Access Code 9 Off Hook Delay OFFHDLY 15 Hook Flash Interval FLINTVL 50 DTMF Tone Length TONELEN 8 Transfer Paging and Screening Parameters Custom Transfer Code XDR Intercom Paging Code C3799N See Section Transfer Release Code when Busy Transfer Release Code when No Answer Call Screening Release Code when Busy Call Screening Release Code when ...

Страница 10: ...ling sequences for your switch 7 0 CONSIDERATIONS ALTERNATIVES The following items should be considered below q Transfers q Disconnect Types q Line Pool Considerations q Intercom Paging q Calling Group Log Out q Trunk to Trunk Transfers 7 1 TRANSFERS Internal calls transferred by Octel 50 do not follow a coverage path they will forward to the console after the number of rings designated in the Tra...

Страница 11: ...xxNR xx the trunk number of the paging trunk port 7 5 CALLING GROUP LOG OUT If the Lucent Merlin Magix loses power or the Voice Mail System is shut down for a period of time the Voice Mail Calling group will log itself out and not direct calls to the Voice Mail To expedite the re login of the Calling Group you must dial each Octel 50 port individually and enter 44 For example if Octel 50 ports are...

Страница 12: ...l trademarks identified by the and are registered trademarks or trademarks respectively of Octel Communications Corporation a subsidiary of Lucent Technologies All other trademarks are the properties of their respective owners The above information is based on knowledge available at the time of publication and is subject to change without notice Printed in the USA Lucent Technologies Inc 1001 Murp...

Отзывы: