The dimensions above are for reference only. The actual size can be slightly different
from the theoretical dimension.
Steps:
7.
Cave the installation hole, and pull the cable out.
The suggested dimension of installation hole is 118(L)
×
108(W)
×
45.5(D) mm.
The suggested length of cables left outside is 100 mm.
Figure 3-9
Cave the Installation Hole
8.
Remove the plastic sheet in the cable entry.
9.
Insert the gang box into the hole and pull out the cables through the cable entry.
Mark the screw holes’ position with a marker, and take out the gang box.
Figure 3-10
Mark the Screw Holes
10.
Chisel 4 holes with drill align to marks on the wall, and insert the expansion sleeves
into the screw holes.
The suggested size of hole is 6 (diameter) × 45 (depth) mm.
11.