- 10 -
GDPD400_V0.3_0920
6. Technical data, specifications
Feature
Unit
Description
Burst pressure, pressure line
bar
800
Ambient temperature
°C
-10…+45°C
Storage temperature
°C
-10…45°C,
Media temperature
°C
-20…+80°C
Maximum relative humidity
% RH
<85% RH without condensation
Connection thread, pressure line
mm
M14x1.5
Thread adapter
mm
M14 x 1.5 to M12 x 1.5
Weight
kg
3.1
Dimensions L x W x H
mm
420 x 520
Feature
Unit
Measurement range (pressure gauge*)
Measurement range relative
bar
0 … 400
Measurement range relative
psi
0 … 5800
Overpressure Pmax
bar
800
Accuracy
% FS
±0.5
*For complete pressure gauge specifications, see the pressure gauge description/operating instructions