background image

 

 

INSTUM_ 04861

 

Page 

1/15 

 

Environmental monitoring solutions

 

 

 

 
 
 
 
 

 

3-axis ultrasonic anemometer 

DNB146 

 

User manual 

Updated 07/03/2022 

 

 

 

 

Содержание DNB146

Страница 1: ...INSTUM_ 04861 Page 1 15 Environmental monitoring solutions 3 axis ultrasonic anemometer DNB146 User manual Updated 07 03 2022...

Страница 2: ...3 2 Analog Output connection 8 2 3 3 Connection to LSI LASTEM data logger 8 3 Configuration 9 3 1 Connecting PC to the sensor 9 3 2 Accessing the configuration 10 3 3 Disabling compass 10 4 LSI Lastem...

Страница 3: ...dbus RTU protocol The anemometer can be connected to LSI LASTEM acquisition systems or any other device using such kind of input 1 2 Technical specifications DNB146 Wind speed Principle Ultrasounds Me...

Страница 4: ...ure 40 60 C Protection degree IP 66 Weight 1500 g Housing Luran aluminum Mounting On mast 33 mm On mast 55 mm using DNB192 adapter not included Data logger compatibility Analog outputs M Log code ELO0...

Страница 5: ...t or to possible other products connected with it To avoid any damages use this product exclusively ac cording to the instructions herein contained The installation and maintenance procedures must be...

Страница 6: ...etallic objects it must be positioned with the metal sup port opposite the connector facing Nord 4 Once the align ment is complete fix it on the sup port mast by tight ening the cable tie at the bot t...

Страница 7: ...RX Pole B RS 485 Rx B RS 422 White Green W DATA RX Pole A RS 485 Rx A RS 422 Grey X SG Ground RS 232 Yellow Y TXD Tx data RS 232 White Yellow L RXD Rx data RS 232 Yellow Brown E OUTV1 Analog Out volta...

Страница 8: ...rial connection For more information regarding RS 485 consult the EIA Electronic Industries Association 2 3 2 Analog Output connection 2 3 3 Connection to LSI LASTEM data logger For the wiring connect...

Страница 9: ...ID Modbus address 1 3 1 Connecting PC to the sensor By means of a terminal emulation program such as Windows Hyper terminal it is possible to modify the sensor configuration parameters from the PC by...

Страница 10: ...ssigned to each item Upon selection a submenu is opened or the selected parameter is displayed with its value Changes to values are confirmed with Enter or discarded with Esc If no key is pressed on t...

Страница 11: ...of the measures to distinguish them from each other o In the Elaborations tab choose the desired elaborations Save the configuration and send it to the data logger 4 2 Use of digital output To use the...

Страница 12: ...ded by the relative multiplication fac tor Error codes table Error code Description Anomaly 1x First pair lower transducer error 2x First pair upper transducer error 3x Second pair lower transducer er...

Страница 13: ...ultimeter to the second output wind direction 6 Subject the sensor to the air flows with the angles 0 90 180 and 270 checking the correspond ing current values as indicated in the following table Air...

Страница 14: ...drate 9600 bps Parity None and that the PC serial port used is COM1 modpoll a 1 r 1 c 8 t 3 COM1 Enter The program displays the measurement values in the following order Wind Speed Wind Direction Elev...

Страница 15: ...onmental protection and collection LSI LASTEM recommends handling the product as waste of electrical and elec tronic equipment RAEE For this reason at the end of its life the instrument must be kept a...

Отзывы: