background image

MDR DMX512/RDM Data Splitter Operator Manual  

 

 Page 6 

LSC Lighting Systems (Aust) Pty Ltd. 

 

 

 

 

 

RDM Explained 

RDM is an acronym for Remote Device Management which is a relatively new protocol that 
overlays on the existing DMX512-A cable network, using the same 3-pins of the XLR 
connector. The protocol has been released under the standard ANSI-E1.20-2006. Equipment 
connected to the DMX512-A network wishing to use the advantages of RDM, must be RDM 
compatible. 

 

Unlike DMX512-A, RDM is bi-directional 

 meaning messages sent out can be responded to 

and reported back to the originator. This can allow RDM controllers to interrogate, control 
and report on any RDM enabled devices on the network, by: 

 

changing DMX start addresses 

 

reporting faults 

 

changing fixture mode settings 

 

requesting a list of fade curves available from a dimmer rack 

 

report on lamp hours usage per fixture 

 

temperature reporting of dimmers and other connected devices 

 

and so on…..

 

 

RDM will allow a lighting console to discover all the devices connected to its outputs and 
even to know how many DMX slots each item requires. This information could then be used 
to auto-patch the entire rig. The user settings of all the devices could be saved as part of 
the show file, so that when the show is re-loaded into the console, the system could ensure 
that all devices are still connected and working, then check that the Pan invert settings and 
custom dimmer curves on certain devices have not changed. In the case of a faulty moving 
light, a new light could be connected and the user settings (eg. DMX address, mode, Tilt 
invert) automatically uploaded to the new unit. 

 

RDM is backwards compatible with existing DMX512 equipment, allowing non RDM devices 
to be connected to the same cable as RDM devices. The non-RDM units, if fully conforming 
to the DMX512-A standard, will simply ignore all the RDM data. The only exception to the 
rule is DMX512-A data splitters. Non RDM units will simple block (stop) all RDM data from 
any devices connected downstream of the DMX512-A splitter. Therefore any lighting system 
using RDM 

must use

 RDM enabled DMX512-A data splitters. 

 

Once the uptake of RDM by other manufacturers reaches levels where the majority of 
equipment is RDM compatible, the advantages of RDM will become obvious and many users 
will wonder how we survived without it.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                 

Содержание MDRJ

Страница 1: ... Document Number MDR T0U A1 doc Version 1 1 LSC Lighting Systems Aust Pty Ltd ABN 21 090 801 675 Building 3 66 74 Micro Circuit Dandenong South Victoria 3175 Australia Tel 61 3 9702 8000 Fax 61 3 9702 8466 email info lsclighting com web www lsclighting com ...

Страница 2: ......

Страница 3: ...DMX when you need it The range encompasses a 5 way and 10 way 19 Rack Mount configuration as well as a 5 way portable version that can be truss mounted as well as used free standing The two 5 way versions allow the option of adding both RDM and Wireless DMX modules whereas the 10 way only allows the addition of RDM as an option Additionally an installation version comprising all RJ45 style connect...

Страница 4: ...russ or pipe The second method is a factory supplied option consisting of a metal bracket and fixing bolts that allows the splitter to have a coupler or hook clamp attached For either method it is recommended to feed a suitably rated safety wire chain through the end cavities of the splitter and fasten around the pipe truss handrail Fuseholder 0 5 Amp rated fuse Recessed cavity for storing aerial ...

Страница 5: ... splitter Note All outputs are individually isolated from each other as well as the input Isolation is for both data and common connections and provides a galvanic barrier to 1500 Volts Outputs are EMI filtered and current limited to protect against short circuits RDM Operation The RDM module when fitted allows RDM based devices to communicate with each other in bi directional mode interleaved wit...

Страница 6: ...e 2 For Wireless Solutions W DMX models press and release the FUNCTION button to synchronise the receiver to the transmitter device This process may take up to 10 seconds to synchronise Once synchronised the STATUS indicator will illuminate 3 To unlink the receiver from the transmitter press and hold the FUNCTION button until the Status indicator goes off The receiver is now not linked to the tran...

Страница 7: ...etres in length When several DMX streams are required to feed different locations DMX512 splitters must be used These provide multiple isolated DMX512 output streams of the same input stream Note Do not use unscreened microphone or low speed data cables for DMX This can cause problems in the DMX network Make sure the cable conforms to the EIA485 cable requirements by providing the following specif...

Страница 8: ...lots each item requires This information could then be used to auto patch the entire rig The user settings of all the devices could be saved as part of the show file so that when the show is re loaded into the console the system could ensure that all devices are still connected and working then check that the Pan invert settings and custom dimmer curves on certain devices have not changed In the c...

Страница 9: ... Power Supply On LED Yes Yes Yes Yes 19 Rack Mount Chassis Yes Yes No Yes Conforms to CE regulations Yes Yes Yes Yes Disclaimer LSC Lighting Systems Aust Pty Ltd supplies the enclosed information in good faith LSC Lighting Systems Aust Pty Ltd makes no representations or warranties with respect to the contents or use of this manual and specifically disclaims any implied warranties of merchantabili...

Отзывы: