background image

MDR DMX512/RDM Data Splitter Operator Manual  

 

LSC Lighting Systems (Aust) Pty Ltd. 

Page 3

 

 

 

DMX512 Operation 

The 

MDR

 DMX512 data splitters have been designed for quick and easy operation. A brief 

operational instruction is detailed below. 

1.

 

Connect the 

MDR

 DMX512-A data splitter to a suitable power source and apply power. 

The “

POWER

” light will illuminate.

 

2.

 

Connect the DMX512-A source cable into the DMX INPUT connector of the 

MDR

 splitter. 

The “DMX data” light

 next to the connector will illuminate if data is present.    

3.

 

If the 

MDR

 splitter is to be the last device at the end of the DMX512 input cable, then 

press the DMX TERM 

button.    The “DMX 

T

erminate” indicator light will now illuminate.

 

4.

 

If the 

MDR

 splitter is not the last device on the line, the DMX THRU output connector 

can be used to connect an output cable and allow the incoming data stream to continue 
to other equipment downstream. 

5.

 

Connect the required DMX512 output cable/s to the DMX512 output connectors of the 

MDR

 splitter. 

6.

 

DMX512-A data present at the DMX512 input connector is now internally routed to all 
five (ten) DMX512 output connectors and therefore to all devices connected downstream 
from the 

MDR

 splitter. 

Note: All outputs are individually isolated from each other as well as the input.  Isolation is 
for both data and common connections and provides a galvanic barrier to 1500 Volts. 
Outputs are EMI filtered and current limited to protect against short circuits. 

 

RDM Operation 

The RDM module, when fitted, allows RDM based devices to communicate with each other in 
bi-directional mode interleaved with the DMX512-A signal. All Inputs and Outputs use the 
standard DMX512-A connectors and cables. 

1.

 

Connect Power, Input, Thru and Outputs as per the DMX512 section above. 

2.

 

To make the 

MDR

 splitter work in RDM mode, press the RDM Enable switch. The RDM 

Enable indicator light will now illuminate. 

3.

 

When data passes through the 

MDR

 splitter from the controller to a responder, then the 

DMX DATA 

>

 indicator will illuminate. When RDM data passes back through the splitter 

from the responder to the controller, then the RDM DATA 

<

 indicator will illuminate. As 

RDM is bi-directional, it is possible that both indicators may illuminate at the same time. 

4.

 

If RDM data overflows, the RDM ENABLE indicator will begin flashing and the RDM 
function will be disabled automatically

.

 

Note: When an RDM device overflows the RDM data stream, then you must isolate the 
offending device from the network and reset the RDM module in the 

MDR

 splitter by 

pressing the RDM ENABLE switch off, then back on. 

 

Содержание MDRJ

Страница 1: ... Document Number MDR T0U A1 doc Version 1 1 LSC Lighting Systems Aust Pty Ltd ABN 21 090 801 675 Building 3 66 74 Micro Circuit Dandenong South Victoria 3175 Australia Tel 61 3 9702 8000 Fax 61 3 9702 8466 email info lsclighting com web www lsclighting com ...

Страница 2: ......

Страница 3: ...DMX when you need it The range encompasses a 5 way and 10 way 19 Rack Mount configuration as well as a 5 way portable version that can be truss mounted as well as used free standing The two 5 way versions allow the option of adding both RDM and Wireless DMX modules whereas the 10 way only allows the addition of RDM as an option Additionally an installation version comprising all RJ45 style connect...

Страница 4: ...russ or pipe The second method is a factory supplied option consisting of a metal bracket and fixing bolts that allows the splitter to have a coupler or hook clamp attached For either method it is recommended to feed a suitably rated safety wire chain through the end cavities of the splitter and fasten around the pipe truss handrail Fuseholder 0 5 Amp rated fuse Recessed cavity for storing aerial ...

Страница 5: ... splitter Note All outputs are individually isolated from each other as well as the input Isolation is for both data and common connections and provides a galvanic barrier to 1500 Volts Outputs are EMI filtered and current limited to protect against short circuits RDM Operation The RDM module when fitted allows RDM based devices to communicate with each other in bi directional mode interleaved wit...

Страница 6: ...e 2 For Wireless Solutions W DMX models press and release the FUNCTION button to synchronise the receiver to the transmitter device This process may take up to 10 seconds to synchronise Once synchronised the STATUS indicator will illuminate 3 To unlink the receiver from the transmitter press and hold the FUNCTION button until the Status indicator goes off The receiver is now not linked to the tran...

Страница 7: ...etres in length When several DMX streams are required to feed different locations DMX512 splitters must be used These provide multiple isolated DMX512 output streams of the same input stream Note Do not use unscreened microphone or low speed data cables for DMX This can cause problems in the DMX network Make sure the cable conforms to the EIA485 cable requirements by providing the following specif...

Страница 8: ...lots each item requires This information could then be used to auto patch the entire rig The user settings of all the devices could be saved as part of the show file so that when the show is re loaded into the console the system could ensure that all devices are still connected and working then check that the Pan invert settings and custom dimmer curves on certain devices have not changed In the c...

Страница 9: ... Power Supply On LED Yes Yes Yes Yes 19 Rack Mount Chassis Yes Yes No Yes Conforms to CE regulations Yes Yes Yes Yes Disclaimer LSC Lighting Systems Aust Pty Ltd supplies the enclosed information in good faith LSC Lighting Systems Aust Pty Ltd makes no representations or warranties with respect to the contents or use of this manual and specifically disclaims any implied warranties of merchantabili...

Отзывы: