A2C-SG2-M12
WWW.LILLIESYSTEMS.COM
9 of 44
2.2
ADC performance
2.2.1
RMS noise (nV) vs. Gain and data rate
Data Rate
Filter value
Output data
rate [Hz]
Settling time
[ms]
Gain=1
Gain=8
Gain=16
Gain=32
Gain=64
Gain=128
1023
4.7
639.4
270
42
23
13.5
10.5
9
640
7.5
400
320
50
27
17
13
11.5
480
10
300
350
60
35
19
15
12.5
96
50
60
1000
134
86
50
35
29
80
60
50
1050
145
95
55
40
32
32
150
20
1500
225
130
80
58
50
16
300
10
1950
308
175
110
83
73
5
960
3.125
4000
590
330
200
150
133
2
2400
1.25
56,600
7000
3500
1800
900
490
1
4800
0.625
442,000
55,000
28,000
14,000
7000
3450
2.2.2
Effective resolution
Data Rate
Filter value
Output data
rate [Hz]
Settling time
[ms]
Gain=1
Gain=8
Gain=16
Gain=32
Gain=64
Gain=128
1023
4.7
639.4
24
24
24
24
24
23
640
7.5
400
24
24
24
24
23.5
22.5
480
10
300
24
24
24
24
23.5
22.5
96
50
60
23.5
23
23
22.5
22
21.5
80
60
50
23
23
22.5
22.5
22
21
32
150
20
22.5
22.5
22
22
21.5
20.5
16
300
10
22.5
22
22
21.5
21
20
5
960
3.125
21.5
21
21
20.5
20
19
2
2400
1.25
17.5
17.5
17.5
17.5
17.5
17.5
1
4800
0.625
14.5
14.5
14.5
14.5
14.5
14.5
2.3
Conformity
IEC 60721-3-5
Climate
Biological
Chemically active substances
Mechanically active substances
Contaminating fluids
Mechanical conditions
Tests are ongoing