Example
Rated frequency = 60Hz
Rated RPM = 1740rpm
Number of motor poles= 4
Hz
f
s
2
120
4
1740
60
=
×
−
=
10.6 Slip compensation
Group
LED Display
Parameter Name
Set
value
Min/Max
Range
Factory
Defaults
Unit
Function
group 2
H30
[Motor type select]
-
0.2/2.2
-
H31
[Number of motor poles]
-
2/12
4
H32
[Rated slip frequency]
-
0/10
-
Hz
H33
[Motor rated current]
-
1.0/12
-
A
H34
[Motor No Load Current]
-
0.1/12
-
A
H36
[Motor efficiency]
-
50/100
-
%
H37
[Load inertia rate]
-
0/2
0
H40
[Control mode select]
1
0/3
0
Set H40 – [Control mode select] to 1 {Slip compensation}.
This function enables the motor to run in constant speed by compensating inherent slip in an induction motor.
If motor shaft speed decreases significantly under heavy loads then this value should be increased.
H30 : Set the motor type connected to the inverter.
H30
[Motor type select]
0.2
0.2kW
0.4
0.4kW
0.75 0.75kW
1.5
1.5kW
2.2
2.2kW
H31 : Enter the pole number on the Motor nameplate.
Frequency
Run
command
Dwell time
Dwell freq.
Start freq.
Содержание SV iC5 Series
Страница 8: ...Table of Contents viii SV iC5...
Страница 22: ...3 Wiring 3 6 SV iC5 Notes...
Страница 38: ...5 Programming keypad 5 14 SV iC5 Notes...
Страница 42: ...6 Basic operation 6 4 SV iC5 Notes...
Страница 64: ......
Страница 68: ......
Страница 108: ...10 Advanced functions 10 20 SV iC5 Notes...
Страница 132: ...13 Troubleshooting Maintenance 13 6 SV iC5 Notes...
Страница 136: ......
Страница 142: ......
Страница 143: ......