To programme the transmission code from remote proceed as
follows: send the radio control code continuously for more than
10 seconds and the control unit will enter the programming
mode as described above for the CODE LED in the main
menu.
The control unit is supplied by the manufacturer with remote
programming of the transmission code not enabled; to enable
the function proceed as follows: check that the extended menu
1 is enabled (the T. MOT. and T. PAUSA LEDs start flashing
alternatively), use the SEL key to navigate to the CODE when
the corresponding LED is flashing and press the SET key: the
CODE is enabled and programming is complete. Repeat the
operation to restore the previous configuration.
B) PED. CODE.
(Step-by-Step / Automatic Operation):
The control unit is supplied by the manufacturer with the
Automatic operation function disabled. To enable the function
proceed as follows: check that the extended menu 1 is
enabled (the T. MOT. and T. PAUSA LEDs start flashing
alternatively), use the SEL key to navigate to PED. CODE
when the corresponding LED is flashing and press the SET
key: the PED. CODE LED lights up and programming is
complete.
By using both the radio control and the low voltage push-
button station to control the shutter, the following operation
may be obtained: the first press opens the shutter until the
programmed motor time elapses while the second press
closes it; if a button is pressed before the programmed motor
time has elapsed, the control unit
inverts
the motion, whether
during the opening or closing process. Repeat the operation to
restore the previous configuration.
C) INB. CMD. AP (
Maintaining Hydraulic Motor Pressure
):
The control unit is supplied by the manufacturer with the
hydraulic motor pressure maintenance disabled. To enable the
function proceed as follows: check that the extended menu 1
is enabled (the T. MOT. and T. PAUSA LEDs start flashing
alternatively), use the SEL key to navigate to INB. CMD. AP.
when the corresponding LED is flashing and press the SET
key: the INB. CMD. AP. LED lights up and programming is
complete. In this way the control unit will send a closing
command to the motor every 2 hours for 2 seconds. Repeat
the operation to restore the previous configuration.
D) LAMP/CORT (Electronic Brake):
The control unit is supplied by the manufacturer with the
electronic brake function disabled. To enable the function
proceed as follows: check that the extended menu 1 is
enabled (the T. MOT. and T. PAUSA LEDs start flashing
alternatively), use the SEL key to navigate to LAMP/CORT.
when the corresponding LED is flashing and press the SET
key: the LAMP/CORT. switches on and programming is
complete. The control unit reduces the forward motion of the
gate due to inertia in the presence of a stop or inversion
command. Repeat the operation to restore the previous
configuration.
EXTENDED MENU 2
The control unit is supplied by the manufacturer with only the
option of directly selecting the functions listed in the main
menu.
To enable the functions listed in extended menu 2, proceed as
follows: access extended menu 1 (as described in the relevant
paragraph), then press the SET button again and hold for 5
seconds; the T. MOT. and T. PAUSA LEDs will flash
simultaneously and the user has 30 seconds within which to
select the functions of extended menu 2 using the SEL and
SET buttons. When this time has elapsed the control unit
returns to the main menu.
EXTENDED MENU 2
LED status LED off LED on
A) CODE 1 sec. inversion time 0.5 sec. inversion time
3) PED. CODE Soft Start = OFF Soft Start = ON
C) INB.CMD.AP User present CH = OFF User present CH = ON
D) LAMP/CORT Input PUL = PUL Input PUL = D.S.
E) T. MOT. Simultaneous flashing beacon ON/OFF
F) T. PAUSA. Simultaneous flashing beacon ON/OFF
A) CODE (Inversion Time Selection 1 s / 0.5 s ):
The control unit is supplied by the manufacturer with the time
taken to invert the rotation movement of the motor set at about
1 second; to increase the inversion speed to about 0.5
second, proceed as follows: check that extended menu 2 is
enabled (T. MOT. and T. PAUSA LEDs start flashing
simultaneously), use the
“SEL” button to navigate to the CODE
LED when flashing and press the
“SET” button: the CODE
LED remains permanently lit and programming is complete.
Repeat the operation to restore the previous configuration.
B) PED. CODE ( Soft Start ) :
The control unit is supplied by the manufacturer with the Soft
Start operation mode disabled. To enable the function proceed
as follows: check that extended menu 2 is enabled (T. MOT.
and T. PAUSA LEDs flash simultaneously), use the
“SEL”
button to navigate to the CODE PED LED when flashing and
press the
“SET” button: the CODE PED LED remains
permanently lit and programming is complete. This means that
at every start of movement, the control unit will govern the way
the motor starts, bringing the power in gradually, from
minimum to maximum in the first 2 seconds of operation.
Repeat the operation to restore the previous configuration.
C) INB. CMD. AP (
User present during closure operation
) :
The control unit is supplied by the manufacturer with the user
present during closure function disabled. To enable the
function proceed as follows: make sure that extended menu 2
is enabled (the T. MOT. and T. PAUSA LEDs flash
simultaneously), use the SEL button to navigate to INB. CMD.
AP. when the corresponding LED is flashing and press the
SET button: the INB. CMD. AP. switches on and programming
is complete. The control unit will now operate in User Present
mode during the closure phase. Repeat the operation to
restore the previous configuration.
D) LAMP/CORT (Selecting Input PUL = PUL / D.S. ):
The control unit is supplied by the manufacturer with Input
PUL = PUL, i.e. with the operation mode for the normal
connection of the command button (NO). If you wish to define
Input PUL = D.S., i.e. with the operating mode for the
connection of a safety device (NC) (intervention during the
opening stage causes the opening gate to stop immediately,
followed directly by a brief inversion of the direction of travel),
proceed as follows: check that extended menu 2 is enabled (T.
MOT. and T. PAUSA LEDs start flashing simultaneously),
press the SEL button until the LAMP/CORT LED flashes and
press the SET button: the LAMP/CORT LED remains
permanently lit and programming is complete.
Warning: connect any safety device only after
programming Input PUL = D.S. If necessary, it is possible
to restore the previous configuration, taking care to
disconnect the safety device first.
RESET:
To restore the default configuration, press the SEL and SET
keys simultaneously, all
RED
LEDs will light up and then
switch off.
DIAGNOSTICS:
Command input test: