Protect Switch 400V motors
Version:
3.0 | 14.02.2021
instruction manual | 1162723-00000
page
9
from
29
4.4
Mechanical properties
DESIGNATION
VALUE
UNIT
Interface Input
1x X-TEC 15 + 1x M12 A-Coded
Interface Output
1x X-TEC 15
Reversing switch
Yes
Installation altitude above
normal zero
2000
m
TYPE OF PROTECTION
IP54
Shock resistance according
to EN 60068-2-27
15g/11ms
Vibration according to EN
60068-2-6
10-500Hz, 0,35mm, 5g
Vibration according to EN
60068-2-64
5-500Hz, 0,75g RMS
Impact resistance Housing
IK08 as per DIN EN 5012/VDE 0470 Part 100
4.5
Thermal properties
DESIGNATION
VALUE
UNIT
Ambient temperature
(operation)
5 to +50
°C
Ambient temperature UL
(operation)
5 to +40
°C
Ambient temperature
(storage)
-25 to +80
°C
4.6
Chemical properties
DESIGNATION
VALUE
UNIT
Housing material
Polycarbonate, glass fibre reinforced
Burning behaviour Housing
5VA in accordance with UL 50 / UL 746C, V-2 in accordance with UL
94, 960°C in accordance with VDE 0471 / EN 60695
Max. relative humidity
95% in case of 25°C and 50% in case of 40°C
stability
UV/weather/weak acid/alcohol/mineral oil/ammonia gaseous/greases
4.7
Approval
DESIGNATION
VALUE
UNIT
UL/CSA Standards
UL 508 C22.2 No. 14
UL Certificate Number
NMTR/7.E506682
SCCR
50kA (480VAC (fuse 30A class CC / 30A class J (High-Fault))), 5kA
(480VAC (fuse 20A RK5 (Standard-Fault)))
policies
RoHS Directives, REACH Regulation