Harmony

Series C

FOCUSED ON WHAT MATTERS

lpamedical.com

2527 Dalton avenue, Quebec (Qc)  G1P 3S6 CANADA 
T 418-681-1313   1-800-663-4863   F 418-681-4488

Содержание Harmony C Series

Страница 1: ...1 INSTRUCTION MANUAL recliner Harmony Series C FOCUSED ON WHAT MATTERS lpamedical com 2527 Dalton avenue Quebec Qc G1P 3S6 CANADA T 418 681 1313 1 800 663 4863 F 418 681 4488...

Страница 2: ...into an aesthetic design that helps maintain the user s dignity and well being Please read this instruction manual carefully and consult it often to maximize the benefits of your LPA chair If you have...

Страница 3: ...ions 9 Wheels 9 Seat to Floor Height 11 Seat Depth 12 Backrest Angle 13 Backrest Tilt and Leg Rest Elevation 14 Activation by User 14 Uprighting Backrest by User 15 Activation by Caregiver 16 Uprighti...

Страница 4: ...in its entirety It is the responsibility of caregivers including family or loved ones using this chair to follow the instructions in this manual at all times and to ensure proper care and maintenance...

Страница 5: ...chair designed for users in short term care different units in hospitals it makes it easy to take specific samples and treatments Theabilitytodeploythebackresttiltsimultaneouslywiththelegsupport elev...

Страница 6: ...roperlybyaqualifiedpersonorsupervisedbythisperson Incaseswhere thepatientisrestless in chairbehaviorshouldbeobservedtoassessthe risks Inaddition thechairmustnotbeplacedwithinreachofguardrails bed rail...

Страница 7: ...that the products you use are compatible Thechairshouldnotbepressure washedorplacedinsideawashing machine Thesepracticesmaycausethechaircomponentstorust internally aswellasdeterioratetheadjustmentcom...

Страница 8: ...e seating and leg support cushion G Wide armrest POSSIBLE ADJUSTMENTS 1 The seat to floor height is adjustable from 17 to 20 445 mm to 521 mm in 1 inch increments 2 The initial seat to floor angle is...

Страница 9: ...r foot to push down the red activation levers on both rear wheels and on the left front wheel WARNING BEFORE HANDLING OR MAKING ADJUSTMENTS ALL 3 BRAKES MUSTBEAPPLIEDASSOONASTHECHAIRISNOTUSEDFORMOVING...

Страница 10: ...ed with a minimum risk of injury to the caregiver Moving an armchairusingtherearwheelstoinitiateturnsrequiresalittlepractice but ensures that the patient s weight has little impact on the effort to tu...

Страница 11: ...nd ankles are at 90 degrees Their feet must make good contact with the floor 3 Remove the 2 front bolts and position the seat support at the desired height BE SURE THAT BOTH SIDES ARE THE SAME LEVEL R...

Страница 12: ...bolts Adjust both sides to the same depth 3 Re tighten the bolts you had loosened on both sides 1 2 1 2 Theseatdepthadjustment from17 to18 isdoneaccordingtothe lengthoftheuser sleg Itisimportantthatth...

Страница 13: ...ack Adjust the backrest tilt for a comfortable positionwiththelowerbacksupportedaswellastheheadsothatthere is a good field of vision in front of you A neck rest optional can be used it attaches to the...

Страница 14: ...order to activate the leg rest once seated in the chair apply pressure to the armrest with your arms to push your body backwards This will activate the mechanism and open the leg rest 2 To tilt the ba...

Страница 15: ...pulling slightly on the armrests with your arms 2 To close the leg rest apply downward pressure with your legs on the leg rest Pull lightly on the end of the armrest simultaneously with your hands so...

Страница 16: ...2 The caregiver then pushes back on the backrest with one hand while the other hand leans on the armrest while transferring their weight from one leg to the other This maneuver will cause the backrest...

Страница 17: ...and while the other hand leans on the armrest while making a slight lateral weight transfer from one leg to the other This maneuver will upright the backrest 2 The caregiver squats with their back str...

Страница 18: ...chair is identified by a serial number Always provide your LPA chair s serial number when ordering replacement parts The serial number can be found on a label attached to the left beam under the seat...

Страница 19: ...leg rest C C11 Raised armrest for bloodwork AB 08 H Profiled headrest AC 04 Activity table cushion covering RB 18 Neck rest RA 03 Table restraint straps not a restraining device RA 03A Full body rest...

Страница 20: ...de your seat to the front of the chair Bring your feet under the seat Place your hands on the armrests Lean forward at your trunk while looking straight ahead SITTING DOWN To sit down in the Harmony c...

Страница 21: ...d damage during this period will void the LPA Medical Inc warranty Additional costs of handling and or using a platform when unloading may apply and are at the customer s expense RETURNS Merchandise t...

Страница 22: ...Model serial and part 2 Purchase date and invoice number 3 Description of the problem The useful lifespan of an LPA chair is estimated to be 10 years OUR COMMITMENT LPAMedicalinc agreestoprovidereplac...

Страница 23: ...ushion C 207 C C2 24 CU 10 Black vinyl left elbow support cushion C 207 C C2 25 CP 1510 Pair of inner protective cushions C 207 C C7 26 CP 1610 20 C C1 side table 27 CP 1620 20 Elbow rest height adjus...

Страница 24: ...24 VUE CLAT E EXPLODED VIEW 15 18 25 28 36 37 38 1 3 9 11 13 12 14 16 19 20 21 29 33 34 30 31 32 40 39...

Страница 25: ...25 2 4 5 6 7 21 5 17 8 10 26 27 22 23 8 24 35...