If the operator is able to start the engine from the platform and it
is clear to lower the boom sections down:
If the engine cannot be started from the platform:
Technical advice and training courses:
1
Pull the Emergency Stop Switch out on the
platform control panel.
2
Start the engine by using the Start Switch.
3
Operate and hold down the Foot Switch.
4
Operate required Function controls to lower
the boom sections.
1
Pull Emergency Stop Switch out.
2
Press and hold down the foot switch.
3
Operate and hold the Auxiliary Power Switch
while simultaneously operating Function
Switch until the boom sections are lowered.
If the controls do not function or you are unsure of their operation please call our Technical Support team on 0845 745 0000
option 2.
As the UK’s largest training provider in our industry, we have a range of courses to help you and your operators to work
effi ciently and safely at height.