background image

C

D

If there are no obstructions and the engine is functional:    

In order of preference, always attempt C before attempting D   

 

 

 

In the case of engine failure, obstructions or trapped operator:

Warning: do not hold onto or place any part of the body through the scissor arms due to crushing risk.

In the case where the boom cannot be directly lowered or if the operator is trapped, it is necessary to 

use the Auxiliary Power Function until the boom is clear. This will give the rescuer more precise 

control of each function. Once all obstructions have been cleared normal operation of the boom 

using the engine should be resumed.

1  

Check for any obstructions.

2  

Switch the Key Switch fully clockwise 

to “ground” position.

3  

Pull out or twist Emergency Stop.

4  

Start engine using Start Switch.

Position the Engine Speed Switch to 

fast speed (denoted by hare symbol).

6  

Push and hold in the Function Enable Switch.

7  

Operate and hold desired Boom Function 

Switch (an alarm should sound to indicate 

boom is being lowered).

1  

Check for any obstructions.

2  

Switch the Key Switch fully clockwise to 

“Ground” position.

3  

Pull out or twist Emergency Stop.

4  

Push and hold the Auxiliary Power Switch 

while simultaneously operating and holding 

the required Function Switch until the boom 

sections are lowered.

(Panels may vary slightly in appearance depending 

on year and model but all have the same functions)

Emergency 

Stop Switch

Engine 

Speed 

Switch

Start 

Switch

Function 

Enable 

Switch

Function 

Switches

Key Switch Ground Position

Auxiliary 

Switch

Function 

Switches

Key Switch 

Ground Position

Emergency 

Stop Switch