53
NOTE:
You DO NOT have to calibrate all five points to complete the
calibration and you can calibrate the points (Empty Level, 1
Quarter Level, Half Level, 3 Quarter Level and Full Level) in any
order you wish.
Remember: Points that are not calibrated will not be
as accurate as points that have been calibrated.
For the greatest
accuracy, we recommend all five points be calibrated.
To execute 5-Point calibration:
1. Press
MENU
, select
S
YSTEM
S
ETUP
and press
MENU
.
2. Highlight
B.
D
EVICES
and press
MENU
, which will open the Bus
Devices list.
3. Highlight the fluid level sensor you want to calibrate and press
MENU
, then select
C
AL
(Calibrate) and press
MENU
. The Points menu
will appear with three options: 2, 3 and 5.
4. Select
5
and press
MENU
. The Points menu will appear with five
options: Empty lev, 1 Qtr lev, Half lev, 3 Qtr lev and Full Lev.
5. Highlight
E
MPTY
L
EV
and press
MENU
. The following message will
appear:
Tnk to Empty lev hit Menu
. Press
MENU
and fill up one quarter
of the tank. If you had a 100 gallon tank, you would add 25 gallons.
6. Repeat steps 1-4, then select
1
Q
TR
L
EV
from the Points menu and
press
MENU
. The following message will appear:
Tnk to 1 Qtr lev hit
Menu
. Press
MENU
and fill up the tank halfway. If you had a 100 gallon
tank, you would add another 25 gallons.
7. Repeat steps 1-4 to access the Points menu, then highlight
H
ALF
L
EV
and press
MENU
. The following message will appear:
Tnk to Half lev hit
Menu
. Press
MENU
and fill up three quarters of the tank. If you had a
100 gallon tank, you would add another 25 gallons.
8. Repeat steps 1-4 to access the Points menu, then highlight
3
Q
TR
L
EV
and press
MENU
. The following message will appear:
Tnk to 3 Qtr lev
hit Menu
. Press
MENU
and fill up the tank. If you had a 100 gallon
tank, you would add another 25 gallons.
9. Repeat steps 1-4 to access the Points menu, then highlight
F
ULL
L
EV
and press
MENU
. The following message will appear:
Tnk to Full lev hit
Menu
. Press
MENU
and let the menus time out, which will take you to
the main display.
Reset Calibration
The Reset Calibration command allows you to reset a fluid level's
calibration settings back to factory defaults. You should only
recalibrate when you believe your EP-15 Fluid Level calibration is
incorrect.