37 

4. Highlight 

U

NSET 

E

NGINE

 and press 

MENU

 which will launch the 

following message: 

Hit Menu to Unset Dev Name.

 

 

5.

 

Press 

MENU

 and you will be taken back to the Bus Devices list.  

To reconfigure an EP-10 Fuel Flow: 

You will use the Change Engine command to reconfigure a Fuel Flow. 

Change Engine, however, will only appear on your LMF-200 menu if 

you have more than one engine. If all the fuel flows on your vessel are 

configured, you will have to unconfigure a fuel flow to free up its 

configuration name (Port, Cen, Stbd).   

If all three fuel flows are configured, which means there is no name 
configuration available, follow the first set of instructions. If the desired 
configuration name is available, follow the second set of instructions

Change Engine (Active only with multiple-engine setting) 

The steps below show how to switch the configuration name of a fuel 

flow from the Port engine to the Starboard engine.  

If all fuel flows configured (Configuration name unavailable): 

1. Press 

MENU

, use the 

UP

 and 

DOWN

  keys  to  select 

S

YSTEM 

S

ETUP

 and 

press 

MENU

.  

2. Highlight 

B.

 

D

EVICES 

and press

 

MENU

. The Bus Devices list will 

appear. 
3. Select the Port FFlow and press 

MENU

4. Highlight 

U

NSET 

E

NGINE

 and press 

MENU

. The following message will 

appear: 

Hit Menu to Unset Dev Name. 

5. Press 

MENU

 and you will be taken back to the Bus Devices menu, 

where fuel flow (formerly Port FFlow) now will be displayed as UnCfg 
FFlow. 

Remember:

 

If the fuel flow you just unconfigured is not shown on 

the Bus Devices the list, you will have to refresh the list. Let the Bus 
Devices list time out then access it again. 

6. Highlight 

S

TBD 

FF

LOW

 and press 

MENU

. Select 

C

HANGE 

E

NGINE

 and press 

MENU

, which will open the Select Engine menu with up to three 

options: Port, Cen, Stbd. 
7. Highlight 

P

ORT

 and and press 

MENU

.  

8. You will be taken back to the Bus Devices list, where the fuel flow 

you selected (formerly Stbd FFlow) will now be shown as Port FFlow. If 

the newly configured fuel flow is not shown, refresh the Bus Devices 

list. 
9. Now, select 

U

N

C

FG 

FF

LOW

 and press 

MENU

. The following message will 

appear: 

Hit Menu to Cfg Flow Sns. 

10. Press 

MENU

, which will open the Select Engine menu. Highlight 

Содержание LMF-200

Страница 1: ...Pub 988 0064 362 www lowrance com LMF 200 Multi function Gauge Installation and Operation Instructions...

Страница 2: ...eNet is a trademark of Lowrance Electronics Inc NMEA 2000 is a registered trademark of the National Marine Electronics Association Lowrance Electronics may find it necessary to change or end our polic...

Страница 3: ...rk Information 9 Understanding this Manual 10 Up and Down keys 10 Menu key 10 Menu Commands 10 Instructions Menu Sequences 10 Section 3 Operation 11 Boat Setup 11 Timeout 12 Basic Menu 12 Pages 12 Vie...

Страница 4: ...Fuel Setup 27 Refill Tank Refill T 27 Partial Fill Part Fill 27 Economy Speed Eco spd 28 Fuel Remaining Source FRem Src 28 Reset Trip Fuel Rst trip f 29 Reset Seasonal Fuel Rst Seas 29 Customizing Pa...

Страница 5: ...50 EP 15 Fluid Level Calibration 51 2 Point Calibration 51 3 Point Calibration 52 5 point Calibration 52 Reset Calibration 53 Calibrating Fuel Flow in a Suzuki Engine Interface 54 Engine Interface Ac...

Страница 6: ...iv Notes...

Страница 7: ...rs and other NMEA 2000 devices connected to the network A NMEA 2000 network using LowranceNET components All Lowrance NMEA 2000 capable devices are either NMEA 2000 certified or certification is pendi...

Страница 8: ...get the latest product information including updated operation manuals instruction sheets and software you can download free of charge When you are ready to expand your network see the accessory order...

Страница 9: ...d read over the entire installation section before drilling any holes in your vessel Recommended Tools and Supplies Recommended tools for this job include hole saw 2 1 8 54 mm hole saw bit drill 1 8 3...

Страница 10: ...zzer piezo and its wire route 4 If you want to turn on the gauge s backlight whenever you turn on your dashboard lights locate your boat s dash light switch and determine how to route the gauge s dash...

Страница 11: ...o wiring diagrams on the following page NOTE Later model LMF 200 gauges have different color wires so examine the wiring diagrams carefully before connecting any wires Use two cable ties and attach th...

Страница 12: ...the dash lights and connect the black dash light wire to ground NOTE If multiple gauges are connected to the same NMEA 2000 bus only one gauge has to be connected to the dashboard lights for all gaug...

Страница 13: ...s network connection nodes at various locations around your boat Compatibility You will easily be able to connect your unit to both red DeviceNet and blue connector networks regardless of whether your...

Страница 14: ...ator or between two backbone extension cables The red connector network below is built in the same way Notice the Double T connectors on the red connector network If you want to add a node at the end...

Страница 15: ...e consistent among the sensors in the LowranceNet Follow the Boat Setup procedure in Section 3 Operation Additional Network Information For more detailed information about setting up a NMEA 2000 netwo...

Страница 16: ...When instructed to press the menu key menu is shown as MENU just as the up and down keys are shown as UP and DOWN Menu Commands A menu command or a menu option will appear in small capital letters lik...

Страница 17: ...ame engine tank configuration you WILL NOT have to go through boat setup when adding a new gauge to the network After adding the gauge to the network the Boat Setup menu will be cleared from the scree...

Страница 18: ...reset amount of time There are four intervals from which to choose 3 5 10 and 15 seconds If for example you chose a timeout interval of 15 seconds the page will be cleared from the screen 15 seconds a...

Страница 19: ...tions The LMF 200 has 9 different pages that may be added to the page screen rotation They are Engine Trim Engine Diagnostics Fuel Manager GPS Position Single Digital Dual Digital Gauge Synchronizer T...

Страница 20: ...to display a wide assortment of data that includes Fluid Level Engine Voltage Engine Trim and Water Speed Synchronizer The Synchronizer page displays RPM for two or three engines It allows users to sy...

Страница 21: ...een before accessing the Remove Pages command from the Pages menu To remove a page from the display 1 First scroll the page you want to remove on to the screen 2 Press MENU use the UP and DOWN keys to...

Страница 22: ...The Set Pop up menu will appear with three options Pages Threshold and Stay Time 3 Select PAGES and press MENU to open the Pop up Pages menu with four options RPM Engine Trim Trim Tabs and Rudder 4 H...

Страница 23: ...ss MENU 2 The Set Pop up menu will appear with three options Pages Threshold and Stay Time Select THRESHOLD and press MENU 3 To set the threshold for RPM highlight RPM and press MENU 4 Use the UP and...

Страница 24: ...U 4 Use the UP and DOWN keys to choose a threshold between 3 and 40 degrees Press MENU and you will be taken back to the main display Screen The Screen menu allows you to adjust the appearance of the...

Страница 25: ...EN 2 Press MENU highlight CONTRAST and press MENU The Contrast Vertical Adjustment bar will appear 3 Use the UP and DOWN keys to move the slider bar to a desired level 4 Press MENU to accept the new s...

Страница 26: ...select AUDIO SETUP and press MENU The audio menu will appear with two options Key Sounds and Alarm Sounds 2 To turn Alarm Sounds on or off select ALARM SOUNDS from the Audio Setup menu and press MENU...

Страница 27: ...TEM SETUP and press MENU 2 Highlight SNR ALARMS and press MENU The Alarm menu will appear with two choices Shallow and Deep 3 Select SHALLOW and press MENU The Shallow Alarm menu will appear with two...

Страница 28: ...ou can return to Boat Setup by resetting the configuration from the Engine Tank Configuration menu To reset Eng Tank configuration 1 Press MENU use the UP an DOWN keys to select SYSTEM SETUP and press...

Страница 29: ...display engine data To modify Engine Data 1 Press MENU use the UP and DOWN keys to select SYSTEM SETUP and press MENU 2 Highlight ENG DATA and press MENU The Engine Data menu will appear with up to th...

Страница 30: ...ead by allowing you to choose a range that will better fit your vessel s speed capabilities If for example your vessel s speed range is 0 40 the unnecessary figures 41 120 will only crowd the gauge di...

Страница 31: ...4 Choose the desired range and press MENU You will be taken back to the main display If you want to set the Pressure Range for other pages that support the Pressure Range feature scroll the desired pa...

Страница 32: ...I Metric 3 Select the desired pressure setting and press MENU which will direct you back to the main display To change Depth units Choosing Depth from the Change Units menu will allow you to set the u...

Страница 33: ...ual amount of fuel in your tank or tanks Refill Tank must be used with the EP 10 Fuel Flow EP 50 Storage Device and the Suzuki NMEA 2000 Engine Interface The Refill Tank command is NOT used when the E...

Страница 34: ...ike the LGC 2000 measures ground speed The EP 25 Paddlewheel and NMEA 2000 Pitot Tube measure water speed NOTE Ground Speed is the default speed source for Fuel Economy To change Economy Speed Source...

Страница 35: ...and take you back to the main display Reset Seasonal Fuel Rst Seas A few sensors like the Suzuki Engine Interface EP 10 Fuel Flow and EP 50 Storage Device keep a running total of fuel used for a seaso...

Страница 36: ...ND S Ground Speed and Tach Tachometer To customize the Single Digital page 1 Use the UP and DOWN keys to scroll the Single Digital page on to the main display 2 Press MENU select CUSTOMIZE and press M...

Страница 37: ...the data boxes on the gauge will flash This indicates the device is not sending data to the network This could occur for a variety of reasons depending on the device type If it is a GPS sensor the GP...

Страница 38: ...the Data menu 3 Highlight the desired data type and press MENU You will be directed back to the main display where the data type you selected will be on the display Trim Tabs The Trim Tab page can be...

Страница 39: ...nd Fluid Level UnCfg FL sensors When they are shown on the bus devices list as UnCfg Tmp UnCfg FF and the UnCfg FL they are unconfigured You can have multiple Temperature sensors and Fluid Level Tanks...

Страница 40: ...Bus Devices list where the temp you unconfigured will be listed as Uncfg Temp To reconfigure an EP 35 temp sensor To reconfigure a sensor there must be a configuration name available Water Outside or...

Страница 41: ...U 2 Highlight B DEVICES and press MENU which will open the Bus Devices list 3 Highlight WTR TEMP on the Bus Devices list and press MENU which will launch the Configuration Options menu 4 Select RECONF...

Страница 42: ...not appear when you are configuring a fuel flow On the Bus Devices list the fuel flow will automatically be given the configuration name Eng FFlow 4 Press MENU which if you have more than one EP 10 F...

Страница 43: ...ress MENU use the UP and DOWN keys to select SYSTEM SETUP and press MENU 2 Highlight B DEVICES and press MENU The Bus Devices list will appear 3 Select the Port FFlow and press MENU 4 Highlight UNSET...

Страница 44: ...gh level alarm for each fuel flow on the network A pop up window will appear if your fuel rises above or falls below a threshold of your choosing 1 Press MENU use the UP and DOWN keys to select SYSTEM...

Страница 45: ...F Tnk S Starboard If you have one tank it will be shown as Fuel Tank Other tanks will be displayed as BlkW Tnk Blackwater FrW Tnk Freshwater O Tnk Oil LW Tnk Live Well and WtW Tnk Waste Water Gray Wat...

Страница 46: ...ist where your newly configured Fluid Level will be listed as F Tnk P F Tnk C or F Tnk S depending on the tank location you chose If you have one tank it will be shown as F Tnk To configure EP 15 Flui...

Страница 47: ...Cfg FLev Sns 3 Press MENU select OIL from the list of fluid types and press MENU That will launch the Tank Size window 4 Input the capacity of the tank gallons and press MENU You will be directed to t...

Страница 48: ...Select a configured Fluid Level from the Bus Devices list and press MENU 3 Highlight UNCONFIG Unconfigure and press MENU which will launch the following message Hit Menu to Unset Dev Name 4 Press MEN...

Страница 49: ...alarm will also work best for Fresh Water and Oil configurations When a tank is configured for Black Water or Waste Water the Level Warning should be set to the High Level If for example you set the...

Страница 50: ...TE If after configuring unconfiguring or reconfiguring an engine interface it is not shown on the Bus Devices list you will have to refresh the list To do this let the menu time out and press MENU Sel...

Страница 51: ...Highlight UNSET ENGINE and press MENU which will launch the following message Hit Menu to Unset Dev Name 5 Press MENU and you will be taken back to the Bus Devices list To reconfigure a Suzuki Engine...

Страница 52: ...be taken back to the Bus Devices list where the engine interface you selected formerly Stbd Eng will now be shown as Port Eng If the newly configured interface is not shown refresh the Bus Devices lis...

Страница 53: ...s MENU After a few moments the Bus Devices list will appear 3 Select an engine interface and press MENU 4 Highlight FUEL WRNG and press MENU The Select Level menu will appear with two options Low Leve...

Страница 54: ...Fuel Used readings are off by more than 3 percent calibration is recommended EP 10 Fuel Flow Calibration The default calibration for an EP 10 Fuel Flow is adequate in most cases but if fuel used read...

Страница 55: ...press MENU The Select Tank menu will open with up to three options Port Cen Center and Stbd Starboard 3 Select the tank you refilled and press MENU The Recalibration ReCal menu will appear with two o...

Страница 56: ...el flow you want to calibrate NOTE It is a good idea to check the calibration of a fuel flow periodically Reset Calibration The Reset Calibration command allows you to reset a fuel flow back to factor...

Страница 57: ...e calibration To execute 2 Point calibration 1 Press MENU select SYSTEM SETUP and press MENU 2 Highlight B DEVICES and press MENU which will open the Bus Devices list 3 Highlight the fluid level senso...

Страница 58: ...librate and press MENU The Points menu will appear with three options 2 3 and 5 4 Select 3 and press MENU The Points menu will appear with three options Empty Lev Half Lev and Full Lev 5 Highlight EMP...

Страница 59: ...would add 25 gallons 6 Repeat steps 1 4 then select 1 QTR LEV from the Points menu and press MENU The following message will appear Tnk to 1 Qtr lev hit Menu Press MENU and fill up the tank halfway I...

Страница 60: ...ound 240 ohms If when the tank is full or empty the ohm readings are significantly different from the standard full 33 1 2 and empty 240 ohms levels there is a problem with the sending unit If the ohm...

Страница 61: ...fuel tank connected to the engine interface you want to calibrate Press MENU use the UP and DOWN keys to select SYSTEM SETUP and press MENU 2 Highlight FUEL MNGR and press MENU Select REFILL T and pre...

Страница 62: ...the fuel used figure Reset Calibration The Reset Calibration command allows you to reset engine interface calibration back to default settings To Reset Calibration 1 Press MENU use the UP and DOWN key...

Страница 63: ...he Add Page segment in Section 3 Operation 1 Make sure the Trim Tab page is on the main display then press MENU to access the Trim Tab page menu 2 Press MENU select CAL TAB and press MENU The followin...

Страница 64: ...58 Notes...

Страница 65: ...59 Notes...

Страница 66: ...60 Notes...

Страница 67: ...the total hours the engine has been used since gauge was installed ENG L Engine Load displays in percent how hard an engine is working ENG O P Engine Oil Pressure shows engine oil pressure readings E...

Страница 68: ...essure displays transmission oil pressure readings USD S Fuel Used Seasonal displays tally of fuel used during a season USD Fuel Used displays fuel used since the last time fuel was added to tank USD...

Страница 69: ...MENT OR REFUND AS JUST DESCRIBED IS THE EXCLUSIVE REMEDY AVAILABLE TO YOU AGAINST US FOR ANY DEFECT MALFUNCTION OR NON CONFORMITY CONCERNING THE PRODUCT OR FOR ANY LOSS OR DAMAGE RESULTING FROM ANY OT...

Страница 70: ...nge or end our shipping policies regulations and special offers at any time We reserve the right to do so without notice in Canada If you re in Canada and you have technical return or repair questions...

Страница 71: ...y to send a product for repair or replacement you must first receive a return authorization number from Customer Service Products shipped without a return authorization will not be accepted When shipp...

Страница 72: ...Visit our web site Lowrance Pub 988 0064 362 Copyright 2006 All Rights Reserved Printed in USA 121306 Lowrance Electronics Inc...

Отзывы: