Wiring |
Installation Manual
Grounding
The grounding terminal is DC isolated from power to eliminate the
risk of galvanic corrosion.
For installations that suffer from noise issues, the grounding
terminal allows for the option to connect to various possible
ground points. The grounding point can be the vessel’s bonded
ground/earth, non bonded RF Ground, or battery minus (DC
negative).
It is recommended to use a 4 mm2 (12 AWG) or thicker wire.
¼
Note:
No DC power will flow through the connected conductor.
LED indicators
The LEDs on the sonar module indicate the status of the module.
LED
Description
Power
Solid green during power up. When started the led
will alternate between green and red.
Ethernet
Flashes when there is network activity.
Transducer
Solid green when active.
OFF when deactivate.