en
en
en
en
46
Parameter list of the Maintenance Me
Parameter list of the Maintenance Me
Parameter list of the Maintenance Me
Parameter list of the Maintenance Menu
nu
nu
nu
Parameter
Parameter
Parameter
Parameter
Read (R)
Read (R)
Read (R)
Read (R)
Write
Write
Write
Write
(RW)
(RW)
(RW)
(RW)
Model
Model
Model
Model
Unit
Unit
Unit
Unit
Min
Min
Min
Min
Max
Max
Max
Max
Default
Default
Default
Default
Description
Description
Description
Description
Language
Language selection
Length Perturb.
RW
MMA
sec
0.1
20
1
When the delay elapses, Delta bar (par 53) checks the pressure value for the set
time. If it remains where it is or increases, the drive stops.
Nom MotorCurrent
RW
MMA
MMW
A
0.45
MMW07: 12
MMA07: 12
MMW12: 19
MMA12: 19
4.5
Set the nominal current of motor. See data plate.
Time Delta bar
RW
MMA
sec
0
80
5,0
Delay during which the inverter attempts to stop. Enabled when pressure and
frequency are constant. Connected with parameter 47.
Pmax NoWater
R
MMA
Watt
30
5000
599
Maximum power input of pump with no flow. Parameter used to monitor pump
operation, particularly in the dry-running condition.
Remote On Enable
RW
MMA
MMW
ON
OFF
OFF
If ON, the driver is enabled to operate via a digital external command, such as a
float switch (contact open = inverter standby). Contact only available in the MMA
version.
Leaks
R
MMA
MMW
N
0
100
Counts the number of times the continuous pump operating time exceeds the
hold time (par 58). By default, so as not to increase the number of leaks, the pump
must not operate for at least 45 mins. within a 24 hour timescale. If the "leaks"
message appears, check whether there are leaks in the system or check times and
settings.
Tot. ShortC Done
R
MMA
MMW
N
0
1000
40
Phase-phase or phase-ground short circuit counter. Default value 40. Reaches 50,
shuts down in the event of a short circuit and shuts down after 10 alarms.
Nominal Value
RW
MMA
MMW
bar
0.3
MMW07: 7.5
MMA07: 10
MMW12: 7.5
MMA12: 10
2.5
Set the required system pressure (set point)
Start Value
RW
MMA
MMW
bar
0.3
MMW07: 7.5
MMA07: 10
MMW12: 7.5
MMA12: 10
2.0
Set the AQUONTROLLER restart pressure following an automatic stop The choice of
the value depends on the type of system. For domestic use, 0.3 bar lower than the
required system pressure (set point) is recommended.
Software Release
R
MMA
MMW
Displays the model of AQUONTROLLER and the software version
Default
RW
MMA
MMW
0
1
0=Cancel
1=Load default parameters
Auto-Start
RW
MMA
MMW
OFF
ON
OFF
ON: AQUONTROLLER will start automatically whenever power is restored to power.
OFF: AQUONTROLLER not start automatically each time power is restored to power. In
this case the activation dell'AQUONTROLLER must be done manually.