The Adjustment of the Static Fuel Pump Timing of Linear Pumps (homemade)
1.
Based on the instructions in Page 17A.04 in the Workshop Manual, make marks to indicate the position when
the piston of the first cylinder is at top dead center. The marks should be made on the gear housing cover and the
pulley respectively.
2.
Dismount the high-pressure fuel pipes of the first cylinder, and pull the fuel amount control bar to its maximum
position. Turn the crankshaft clockwise viewed from the front end of the engine, until the piston of the first
cylinder reaches TDC.
3.
Turn the crankshaft anticlockwise at an angle of over 60°. Then turn the crankshaft clockwise slowly, meanwhile
observe the fuel level in the fuel outlet valve. As soon as the fuel level begins to fluctuate, indicating the
beginning of fuel supply of the first cylinder, you should stop turning the crankshaft. Measure the angle between
the line on the gear housing cover and that on the belt pulley, namely the fuel supply angle. If the latter line is
before the former line, then the fuel is supplied in advance. Otherwise, the fuel supply is retarded.
4.
The fuel supply angles of various types of engines are listed below.
Engine type
110Ti
135Ti
160Ti
180Ti
210Ti
230Ti
Pump type
7100
VE
7100
7100
7100
7100
Fuel Pump
Timing
10°±1°
0
—
1.35 mm 8°±1°
8°±1°
8°±1°
8°±1°
Engine type
1004-4
1004-4T
1006-6T
1004-4TW
1004-4TA
1006-6TW
Pump type
AD
AD
AD
VE
VE
AD
Fuel Pump
Timin
18°±1°
12°±1°
16°±1°
0—
0.3 mm
0—
0.4 mm
14°±1°
Attention:
For The Fuel Pump Timing of different Engine type, contact perkins lovol Engine (Tianjin) co.,Ltd
5.
If the fuel supply angle is not desirable, then it can be adjusted by using the holes on the flange at pump end
after loosening the nuts on the pump bracket and the flange at pump end. The fuel supply angle can be increased
by leaning the pump toward the engine. Otherwise it can be decreased. Corresponding to 1mm distance moved
by the outer edge of the pump flange, the fuel supply angle will be adjusted at about 1°CA.
6.
Once the fuel supply angle becomes suitable, the nuts on the flange at the pump end, and the bolts on the pump
bracket, should be screwed down to the required torque. Then repeat step 3 and check the fuel supply angle.
Note: the arc length corresponding to 1°crank angle=
π
D/360(mm) D—pulley diameter (mm).
10.02
Содержание 1004-4
Страница 3: ...Lovol Phaser Series Lovol 1000 Series...
Страница 4: ...EGR engine of Lovol Phaser Series Engine of Lovol 1000 Series...
Страница 12: ...Engine Views 2 Introduction 2 02 Location of engine parts 2 03 2 01...
Страница 49: ...Fault diagnosis 6 Problems and possible causes 6 02 Code list of possible causes 6 03 6 01...
Страница 52: ...Engine preservation 7 Introduction 7 02 Procedure 7 02 7 01...
Страница 54: ...Parts and service 8 Introduction 8 02 Service literature 8 02 Training 8 02 8 01...
Страница 56: ...Engine data 9 Engine data 9 02 9 01...
Страница 63: ...Structure of PB Pump 10 06...
Страница 65: ...Structure of RSV Governor 10 08...
Страница 75: ...The Use and Maintenance of the Hydraulic Pump 10 08 12 01...
Страница 80: ...4 ECU Wiring principle diagram 13 04...