I506 GB PL 09 17

31100341

G

B

10

 M02 – UTILITY                                                                                                                                                                                                                                UoM                           Default                          Range

 P02.01       Language                                                                                                                                                                                                                                                         English                         English

                                                                                                                                                                                                                                                                                                                               Italiano

                                                                                                                                                                                                                                                                                                                               Francais

                                                                                                                                                                                                                                                                                                                               Espanol

                                                                                                                                                                                                                                                                                                                            Portuguese

                                                                                                                                                                                                                                                                                                                               Deutsch

 P02.02       High backlight level                                                                                                                                                                                                          %                               100                            0-100

 P02.03       Low backlight level                                                                                                                                                                                                          %                                30                              0-50

 P02.04       Low backlight delay                                                                                                                                                                                                          s                                 30                             5-600

 P02.05       Default page return                                                                                                                                                                                                           s                                 60                        OFF / 10-600

 P02.06       Default pag                                                                                                                                                                                                                                                     W + kWh                 VL-L / VL-N …

 P02.07       Default sub-page                                                                                                                                                                                                                                               INST                    INST / HI / LO / 
                                                                                                                                                                                                                                                                                                                             AVG / MD

 P02.08       Display update time                                                                                                                                                                                                          s                                 0.5                          0.1 – 5.0

 P02.09       Exported energy measure                                                                                                                                                                                                                                   OFF                           OFF-ON

 P02.10       Phase energy measure                                                                                                                                                                                                                                       OFF                           OFF-ON

 P02.11       Asymmetry measure                                                                                                                                                                                                                                          OFF                           OFF-ON

 P02.12       THD measure                                                                                                                                                                                                                                                      OFF                          OFF-THD

 P02.13       Power unbalance measurement                                                                                                                                                                                                                         OFF                           OFF-ON

 P02.14       Backlight flash when in alarm                                                                                                                                                                                                                            OFF                           OFF-ON

 P02.15       Reactive power calculation                                                                                                                                                                                                                                 TOT                         TOT-FUND

P02.05

–  If set to OFF, the display always remains on the page where the user left it. If set to a value, after this time the display returns to the page set with P02.06.

P02.06

–  Number of the page that the display returns to automatically once the time P02.05 since a button was last pressed has elapsed. 

P02.07

–  Type of sub-page that the display returns to after P02.05 has elapsed.

P02.09

–  Enables the measurement and display of exported energies (generated towards the mains).

P02.10

–  Enables the measurement and display of energies by individual phase.

P02.11

–  Enables the measurement and display of voltage and current asymmetry.

P02.12

–  Enables the measurement and display of voltage and current THDs (% Harmonic Distortion).

P02.13

–  Enables the calculation and display of phase power unbalance.

P02.14

–  When there is an alarm, the display’s backlight flashes to highlight the fault.

P02.15

–  Selection of reactive power calculation method.

                

TOT:

the reactive power includes the harmonic contributions. In this case: P

reactive

2

= P

apparent

2

– P

active

2

                

FUND:

the reactive power includes the fundamental contribution only. In this case: P

reactive

2

 P

apparent

2

– P

active

2

. P

apparent

still inlcudes the harmonic contribution (same value as TOT case).

                In absence of voltage and current harmonics, both the calculation methods come to the same result and PF = cos

ϕ

.

 M03 – PASSWORD                                                                                                                                                                                                                          UoM                           Default                          Range

 P03.01       Enable passwords                                                                                                                                                                                                                                              OFF                           OFF-ON

 P03.02       User level password                                                                                                                                                                                                                                          1000                          0-9999

 P03.03       Advanced level password                                                                                                                                                                                                                                  2000                          0-9999

 M04 – INTEGRATION                                                                                                                                                                                                                       UoM                           Default                          Range

 P04.01       Integration mode                                                                                                                                                                                                                                               Shift                            Fixed 

                                                                                                                                                                                                                                                                                                                                  Shift

                                                                                                                                                                                                                                                                                                                                  Bus

 P04.02       Power integration time                                                                                                                                                                                                   min                               15                              1-60

 P04.03       Current integration time                                                                                                                                                                                                 min                               15                              1-60

 P04.04       Voltage integration time                                                                                                                                                                                                 min                                1                               1-60

 P04.05       Frequency integration time                                                                                                                                                                                             min                                1                               1-60

 M05 – HOUR COUNTER                                                                                                                                                                                                                  UoM                           Default                          Range

 P05.01       Hour counters general enable                                                                                                                                                                                                                             ON                            OFF-ON

 P05.02       Partial hour counter 1 enable                                                                                                                                                                                                                              ON                       OFF-ON-LIMx

 P05.03       Hour counter 1 channel number (x)                                                                                                                                                                                                                     1                                1-4

 P05.04       Partial hour counter 2 enable                                                                                                                                                                                                                              ON                       OFF-ON-LIMx

 P05.05       Hour counter 2 channel number (x)                                                                                                                                                                                                                     1                                1-4

 P05.06       Partial hour counter 3 enable                                                                                                                                                                                                                              ON                       OFF-ON-LIMx

 P05.07       Hour counter 3 channel number (x)                                                                                                                                                                                                                     1                                1-4

 P05.08       Partial hour counter 4 enable                                                                                                                                                                                                                              ON                       OFF-ON-LIMx

 P05.09       Hour counter 4 channel number (x)                                                                                                                                                                                                                     1                                1-4

P03.01

– If set to OFF, password management is disabled and there is free access to settings and the commands menu. 

P03.02

– With P03.01 active, value to specify to activate user-level access. See Password Access section.

P03.03

– As P03.02, with reference to advanced-level access.

P04.01

– Integrated measurement calculation mode selection. 

Fixed

= The instantaneous measurements are integrated for the time set. Each time that the time set elapses, the integrated measurement is updated with the result of the latest integration.

Shift

= The instantaneous measurements are integrated for a time = 1/15 of the time set. Each time this interval elapses, the oldest value is replaced with the new value calculated. The integrated

measurement is updated every 1/15 of the time set, considering a time-shift window that includes the last 15 values calculated, equivalent in length to the time set.

Bus

= As fixed mode, but the integration intervals are dictated by synchronisation messages sent on the serial bus. (110)

P04.01

– Average (AVG) measurement integration time for active, reactive and apparent power.

P04.03, P04.04, P04.05

– Average (AVG) measurement integration time for the corresponding values.

P05.01

– If OFF, the hour counters are disabled and the hour counter measurement page is not displayed.

P05.02, P05.04, P05.06, P05.08

– If OFF, the partial hour counter (1, 2, 3 or 4) is not incremented. If ON, it is incremented when the energy meter is supplied. If linked to one of the internal variables (LIMn), it is

incremented only when this condition is true.

P05.03, P05.05, P05.07, P05.09

– Channel number (x) of any internal variable used in the previous parameter. Example: If the partial hour counter needs to count the time that a measurement is above a certain

threshold, defined by LIM3, program LIMx in the previous parameter and specify 3 in this parameter.

Содержание DME D330MID

Страница 1: ...achsch den d rfen diese Ger te nur von qualifiziertem Fachpersonal und unter Befolgung der einschl gigen Vorschriften installiert werden Vor jedem Eingriff am Instrument die Spannungszufuhr zu den Mes...

Страница 2: ...AC 3 przyciski do poruszania si po funkcjach i ustawieniach Dioda metrologiczna do wskazywania przep ywu energii Wysoka dok adno pomiar w dokonywanych metod rzeczywistych warto ci skutecznych TRMS Po...

Страница 3: ...ej Aktualn stron mo na rozpozna po tym i w g rnej cz ci wy wietlacza widnieje jednostka miary W zale no ci od zaprogramowania i pod czenia urz dzenia niekt re pomiary mog nie by wy wietlane na przyk a...

Страница 4: ...1 TAR 2 kWh L2 CA K 12 LICZNIKI ENERGII L3 kWh L3 CZ SYS TAR 1 TAR 2 kWh L3 CA K 13 LICZNIKI ENERGII L1 kvarh L1 CZ SYS TAR 1 TAR 2 kvarh L1 CA K 14 LICZNIKI ENERGII L2 kvarh L2 CZ SYS TAR 1 TAR 2 kv...

Страница 5: ...CENIA HARMONICZNE NAPI L N THD V L1 THD V L2 THD V L3 HI LO AV 36 ZNIEKSZTA CENIA HARMONICZNE PR D W THD I L1 THD I L2 THD I L3 HI LO AV 37 LICZNIK GODZIN hhhhhh mm ss CA K CZ 1 CZ 2 CZ 3 CZ 4 38 LIM...

Страница 6: ...ksymalna Warto minimalna Warto rednia Warto chwilowa Warto maksymalna Warto minimalna Warto rednia Warto chwilowa Warto maksymalna Warto minimalna Warto rednia Warto chwilowa Warto maksymalnego zapotr...

Страница 7: ...o e sterowa 2 niezale nymi taryfami poza energi ca kowit i cz ciow Taryfy mo na wybiera zazwyczaj poprzez wej cie cyfrowe lub opcjonalnie poprzez wysy anie komunikat w w ramach protoko ukomunikacji W...

Страница 8: ...z menu komend C 07 Limit w czony Limit wy czony Limit wy czony Limit wy czony Alarm w czony Alarm wy czony Alarm wy czony Kod w czonego alarmu Alarm wy czony Tekst w czonego alarmu Przewijany tekst wy...

Страница 9: ...e nie i Urz dzenie uruchomi si ponownie Je li aden przycisk nie zostanie naci ni ty w ci gu 2 kolejnych minut wyj cie z menu ustawie nast pi automatycznie asystem powr ci do normalnego trybu wy wietla...

Страница 10: ...pi min 1 1 60 P04 05 Czas integracji cz stotliwo ci min 1 1 60 M05 LICZNIK GODZIN JM Domy lne Zakres P05 01 Aktywacja licznika og lnego godzin ON OFF ON P05 02 Aktywacja licznika cz ciowego godzin 1 O...

Страница 11: ...y jest pr g limitu P08 n 02 Okre la dzia anie progu limitu Mo e by nast puj ce Max LIMn aktywny gdy pomiar przekracza P08 n 03 P08 n 06 jest progiem kasowania Min LIMn aktywny gdy pomiar wynosi mniej...

Страница 12: ...r wnie wykonywa operacje automatyczne niezb dne do konfiguracji urz dzenia W poni szej tabeli podano funkcje dost pne dzi ki menu komend podzielone w zale no ci od wymaganego poziomu dost pu Po wybran...

Страница 13: ...SG B TR A SG B TR A SG B TR A SG B TR A SG B TR A ROZMIESZCZENIE ZACISK W I WYMIARY MECHANICZNE mm 90 58 45 5 43 7 S1 S2 I1 I2 S2 S1 S1 S2 I3 T1 T2 SG B A TR V2 V1 V3 VN 72 STEROWANIE ZDALNE Kod zam w...

Страница 14: ...ie udarowe Uimp 6 kV Wytrzyma o na napi cie o cz stotliwo ci przemys owej 4 kV Z cza obwodu zasilania pomiaru i taryfy Typ zacisk w rubowe sta e Liczba zacisk w 4 dla zasilania pomiaru 2 dla wej cia w...

Страница 15: ...r Befolgung der einschl gigen Vorschriften installiert werden Vor jedem Eingriff am Instrument die Spannungszufuhr zu den Messeing ngen trennen und die Stromwandler kurzschlie en Bei zweckwidrigem Geb...

Страница 16: ...ergy meter CT insertion 4U 72 mm modular construction for DIN rail Backlit LCD display Built in RS485 interface AC tariff input 3 navigation buttons for functions and settings Metrology LED for energy...

Страница 17: ...allow the measurement display pages to be scrolled one at a time The current page can be recognized through the unit of measurement shown in the top part of the display Some measurements may not be di...

Страница 18: ...TOT 12 ENERGY METERS L3 kWh L3 PAR SYS TAR 1 TAR 2 kWh L3 TOT 13 ENERGY METERS L1 kvarh L1 PAR SYS TAR 1 TAR 2 kvarh L1 TOT 14 ENERGY METERS L2 kvarh L2 PAR SYS TAR 1 TAR 2 kvarh L2 TOT 15 ENERGY METE...

Страница 19: ...N VOLTAGE HARMONIC DISTORTION THD V L1 THD V L2 THD V L3 HI LO AV 36 CURRENT HARMONIC DISTORTIONE THD I L1 THD I L2 THD I L3 HI LO AV 37 HOUR COUNTER hhhhhh mm ss TOT PAR 1 PAR 2 PAR 3 PAR 4 38 LIMIT...

Страница 20: ...value Minimum value Average value Instantaneous value Maximum value Minimum value Average value Instantaneous value Maximum value Minimum value Average value Instantaneous value Max Demand value Maxi...

Страница 21: ...e 2 independent tariffs in addition to total and partial The tariff is normally selected through the digital input or optionally through messages sent through the communication protocol To select the...

Страница 22: ...larm reset method depends on parameter P09 n 03 This determines whether it can be automatic on the disappearance of the alarm conditions or requires manual intervention through the commands menu C 07...

Страница 23: ...device will reboot If no buttons are pressed for two minutes the setup menu is abandoned automatically and the system returns to the standard display without saving the parameters Remember that solel...

Страница 24: ...P04 02 Power integration time min 15 1 60 P04 03 Current integration time min 15 1 60 P04 04 Voltage integration time min 1 1 60 P04 05 Frequency integration time min 1 1 60 M05 HOUR COUNTER UoM Defa...

Страница 25: ...efines the function of the limit threshold It can be Max LIMn active when measurement exceeds P08 n 03 P08 n 06 is the reset threshold Min LIMn active when measurement is below P08 n 06 P08 n 03 is th...

Страница 26: ...ions that are useful for configuring the instrument The following table lists indicates the functions available in the commands menu divided by access level required Once the required command has been...

Страница 27: ...TR A SG B TR A SG B TR A SG B TR A SG B TR A SG B TR A TERMINALS ARRANGEMENT AND MECHANICAL DIMENSIONS mm 90 58 45 5 43 7 S1 S2 I1 I2 S2 S1 S1 S2 I3 T1 T2 SG B A TR V2 V1 V3 VN 72 REMOTE CONTROL Order...

Страница 28: ...L 09 17 31100341 G B Measurement and tariff power supply circuit connection Type of terminal Screw type fixed Number of terminals 4 for supply measurement 2 for tariff selection input Cable cross sect...