DEVICE DISCOVERY

The Digifact E is by default set to obtain an IP address from the network it is connected to (DHCP), hence it 
must be connected to a suitable DHCP server. To discover the device on a network, the following commands 
need to be run through windows powershell to locate the device name;

dns-sd -B _simic._tcp

NOTE: Apple bonjour needs to be pre-installed on the PC where the powershell commands are being 
executed.

DEVICE DISCOVERY AND DEFAULT PASSWORD CHANGE

Page 4 of 6

LOUROE  ELECTRONICS    6 9 5 5   VA L J E A N   AVENUE,  VAN  NUYS,  CA  91406

TEL  (818)  994-6498

FAX 

994-6458

website: www.louroe.com                          e-mail: [email protected]

   

   

(818)

®

Digifact

_E_mic-inst_01/19

Once the device name has been located, the following script must be run:

dns-sd -G v4 

<devicename>

.local 

to locate the device IP address:

The device IP address can them be typed into an internet browser 

to 

access the device user interface page. 

(Google Chrome is recommended)

 

DEFAULT PASSWORD CHANGE

On first use the default password for the device is;
username: admin
password: admin
After entering the above information, the device will request the user to change the default password

Once the default password has been changed the device prompts to re-enter the new password to login 
to the device. 

Содержание DIGIFACT E

Страница 1: ...ufactured by LOUROE ELECTRONICS to be free of defects in material and workmanship Should a defect appear within one year 12 months from date of shipment LOUROE ELECTRONICS will at its sole discretion repair or replace the defective equipment This equipment shall not be accepted for repair or return without prior notification by LOUROE ELECTRONICS This warranty does not extend to any Louroe product...

Страница 2: ...dB alarm Event triggers Analytics audio level Event actions TCP notification external output activation pre and post alarm audio recording to Network Attached Storage NAS GENERAL Enclosure Power Power over Ethernet IEEE802 3af optional external 5V DC 2A 2 pin header Memory 512 MB RAM Event triggers Audio analytics decibel threshold Event actions TCP notification external output activation pre and ...

Страница 3: ...e pin outs of the power and alarm outputs terminal block are depicted below The external power and alarm output cable assembly should be wired through the provided moisture resistant cable gland to preserve the moisture resistance of the unit Four digital alarm output ports are available for connection to external devices the alarm outputs can be set to trigger from analytic and volume threshold e...

Страница 4: ...VENUE VAN NUYS CA 91406 TEL 818 994 6498 FAX 994 6458 website www louroe com e mail sales louroe com 818 Digifact _E_mic inst_01 19 Once the device name has been located the following script must be run dns sd G v4 devicename local to locate the device IP address The device IP address can them be typed into an internet browser to access the device user interface page Google Chrome is recommended D...

Страница 5: ...vel threshold adjustment of streaming volume level dB adjustment of time and volume over ambient threshold for analytic applications Sound Detector activity Graphic representation of sound activity level and classification for analytic applications of audio signals detected by the device Live audio Allows for enabling disabling of live audio stream played from the speakers of the device from where...

Страница 6: ...ta data transmission to Video Management Systems VMS detailed application notes of adding and configuring devices to VMS s can be found at Network Settings Set the device to a static IP address and configure device IP settings Date and Time configuration Configure devices date time settings Peer devices Used to detect and configure other Louroe devices on the same subnet Status Displays device sta...

Отзывы: