NETWORK, POWER AND OUTPUT CONNECTION
MOUNTING
The Digifact Model E can either be surface mounted or strapped to a pole using the optional Louroe pole
mount accessory kit (not included).
™
INSTALLATION AND CONNECTIONS
Page 3 of 6
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406
TEL (818) 994-6498
FAX
994-6458
website: www.louroe.com e-mail: [email protected]
(818)
®
Digifact
_E_mic-inst_01/19
™
ALARM OUTPUT CONNECTIONS
A moisture resistant
Female Rj45 jack is located on the bottom of the unit for 10BASE-T/100BASE-TX
PoE connection using CAT5/6 cable. If no PoE connection is available (network only) the device can be
powered off 5V DC 2A external power supply (not included). Four alarm outputs are also available,
details of the pin-outs of the power and alarm outputs terminal block are depicted below. The external
power and alarm output cable assembly should be wired through the provided moisture resistant cable
gland to preserve the moisture resistance of the unit.
Four digital alarm output ports are available for connection to external devices, the alarm
outputs can be set to trigger from analytic and volume threshold events. The output ports are
“open drain” type outputs. If used with an inductive load, e.g. a relay, a diode must be
connected in parallel with the load, for protection against voltage transients.
FUNCTION
PIN
NOTES
5V DC
1
Max load 100mA
Output 1
2
Output 2
3
Output 3
4
Output 4
5
1 2 3 4 5
ALARM OUTPUT
+5VDC GND
EXT POWER
Note: Output 1,2,3,4 connect to pin 1 (5V)
when active, floating (unconnected) when
deactivated. If connecting to a “dry
contact” input, a 5V relay should be
connected between the output and input
ports of the two devices.