background image

6955 VALJEAN AVE. VAN NUYS, CA 91406   PH: 818-994-6489  | FAX: 818-994-6485 | [email protected] | WWW.LOUROE.COM

AP-2TB

AUDIO MONITORING BASE STATIONS

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS 

WIRING CONNECTIONS BETWEEN AP-2TB AND REMOTE SPEAKER/

MICROPHONE. (TLM-W is used as an example only. Use same con-

nections for other speaker/microphones units.)

1.  Connect one end of cable to remote speaker/microphone as 

shown in the interconnection diagram.  Use 4 conductor shield-

ed audio cable such as West Penn 356.  Connect wires wrapped 

with overall shield to terminals “A”, “B”, and “C” of Speaker/

Microphone’s terminal block.  When using sample color coded 

cable, connect red wire to terminal “A”; black wire to terminal 

“B” and bare wire to terminal “C”.

2.  Connect the other two wires of TLM-W 70V transformer (twisted 

pair) to the “SP” and “G” of AP-2TB using wire nutts.  Connect 

cable’s green wire to terminal marked “SP”.  Connect cable’s 

white wire to terminal marked “G”.

3.  Connect the other end of the cable to AP-2TB Mic 6-Pin Terminal 

Block [13] for Zone 1.  Make sure that wire connected to terminal 

“A” of remote speaker/microphone connects to terminal “A” of 

AP-2TB’s Mic 6-Pin Terminal Block [13]; wire connected to ter-

minal “B” of speaker/microphone  connects to terminal “B” of 

AP-2TB; “C” to “C”, “SP” to “SP” and “G” to “G”.  Terminal “P” 

of  AP-2TB is used only when paralleling to a second AP-2TB (or 

more). Observe cable color coding.

4.  Repeat connections for Zone 2.

5.  When a recording device is used, connect Audio-OUT Jack [12] 

to recorder’s Audio-IN Jack with an RCA cable (not supplied).

6.  Connect Audio-IN Jack [11] to recorder’s Audio-OUT Jack with 

an RCA cable.

7.  Plug AC Adapter (supplied) to DC-IN Jack [14]

OPERATION AND TEST

1.  First plug DC output of AC Adapter to DC-IN Jack [14],then plug 

AC Adapter to 120 Vac supply.

2.  Turn power to the unit by rotating to ON position, the Power-Vol-

ume Knob[1]. The Power LED[3] will light.

3.   Push in to activate Zone 1 Switch [4]. Zone Switch is lighted in-

dicating two-way audio monitoring is activated. Audio should be 

present at the Monitor Speaker [10].  If there is no audio, with 

a voltmeter, check for 12 Vdc at terminals “A” and “C”.  Place 

positive lead of voltmeter to terminal “A” and negative to “C”.   If 

voltage is not present, there might be a short on the wiring that 

may cause the resettable fuse to open. Check that wires are con-

nected properly to the correct terminals.  Otherwise microphone 

is defective.  Call factory for assistance.  Adjust volume of audio 

by rotation the Power-Volume Knob[1] clockwise to increase or 

counterclockwise to decrease.

4.  Press and hold Talkback Switch [9] and speak into Talkback 

MIC[6]. To increase or decrease the audio heard at the remote 

speaker/microphone unit, rotate Talkback Volume Knob[8] clock-

wise to increase or counterclockwise to decrease. Another per-

son is needed to listen to the volume and clarity of talkback at the 

remote location..

5.  Repeat test for Zone 2.

6.  When a recording device is connected to the unit, press record 

and record live audio into the DVR/VCR.  Press Playback/Mute 

Switch [7] to playback. Switch indicator will light and the audio 

from the remote microphone is muted. The unit is ready for re-

ceiving audio playback from a recorder.

7.  Playback/Mute Switch[7] can be used to mute live audio coming 

from the remote microphone. Audio comes back in when this 

switch is depressed.

AP-2TB (LE-402)

Input sensitivity

(from remote microphone)

0.78Vrms

Input sensitivity

(talkback microphone)

-45 dB

Monitor power output

1

W

 @ 8

Talkback power output

1W into 70V Line

Audio line output impedance

600

  

Audio input impedance

10k

Audio frequency response

100 Hz to 10kHz

Headphone impedance

8Ω to 600

 

Power input

12 Vdc, 500mA

Dimensions

7.9”L x 6.6”W x 2.4”H

Weight

2.09 lbs (0.95kg)

6955 VALJEAN AVE. VAN NUYS, CA 91406   PH: 818-994-6489  | FAX: 818-994-6485 | [email protected] | WWW.LOUROE.COM

Содержание AP-2TB

Страница 1: ...tch Hold down and talk so audio can be heard at the remote Speaker Mic unit 10 Monitor Speaker Monitored audio is heard at this speaker Muted when a headset is plug into Headphone Jack 2 11 Audio In Jack Receives audio from an external source recorded playback from a DVR or VCR 12 Audio OUT Jack Sends audio to an external receiver DVR VCR etc 13 MIC 6 Pin Terminal Connects to speaker microphone at...

Страница 2: ...ut which is standard for most audio applications Should a 600Ω talkback output be required please contact our factory for details regard ing instructions for switching over to 600Ω REAR OF DVR A B C 12Vdc 500mA AUDIO IN AUDIO OUT 12Vdc Power Supply AD 1 LE 242 AUDIO OUT AUDIO IN VIDEO OUT VIDEO IN AP 2TB LE 402 TLM W LE 007 Terminal Block identification of Model AP 2TB Audio Base Station A Red 12V...

Страница 3: ... AC Adapter to 120 Vac supply 2 Turn power to the unit by rotating to ON position the Power Vol ume Knob 1 The Power LED 3 will light 3 Push in to activate Zone 1 Switch 4 Zone Switch is lighted in dicating two way audio monitoring is activated Audio should be present at the Monitor Speaker 10 If there is no audio with a voltmeter check for 12 Vdc at terminals A and C Place positive lead of voltme...

Страница 4: ... MONITORING TECHNOLOGY AP 1TB AUDIO MONITORING BASE STATIONS INSTALLATION AND OPERATING INSTRUCTIONS ABOUT LOUROE ELECTRONICS Located in Van Nuys California and 32 years young Louroe Electronics has been the world leading Audio Manufacturer Our continued growth has resulted from providing innovative products receiving high customer sat isfaction maintaining strict devotion to quality standards and...

Отзывы: