INTERCONNECTION DIAGRAM

WIRING REQUIREMENTS

4  Conductor  consisting  of:  2  Conductor  shielded,  20  

gauge with 22 gauge drain (microphone connection).  

2 Conductor unshielded, 18 gauge (speaker connection) 

All in the same jacket.

NOTE: Model AP-2TB Audio Base Station is supplied 

with a 70V talkback output, which is standard for most 

audio applications.  Should a 600Ω talkback output be 

required, please contact our factory for details regard-

ing instructions for switching over to 600Ω

REAR OF DVR

A   B

   C

12Vdc

500mA

AUDIO 

IN

AUDIO 

OUT

12Vdc Power Supply 

AD-1 (LE-242) 

AUDIO OUT

AUDIO IN

VIDEO OUT

VIDEO IN

AP-2TB 

(LE-402)

TLM-W 

(LE-007)

Terminal Block identification of Model AP-2TB Audio Base Station

A

Red

12Vdc

B

Black

Audio Input

C

Bare

Ground Mic

SP Green Speaker Positive

G

White Speaker Negative

P

Not used with this application.

Built in Microphone Connection

A

Red

12Vdc

B

Black

Audio Output

C

Bare

Ground Mic

A B C SP G P

70V Transformer

Wire NUTS

Green (Positive)

White (Negative)

Содержание AP-2TB

Страница 1: ...tch Hold down and talk so audio can be heard at the remote Speaker Mic unit 10 Monitor Speaker Monitored audio is heard at this speaker Muted when a headset is plug into Headphone Jack 2 11 Audio In Jack Receives audio from an external source recorded playback from a DVR or VCR 12 Audio OUT Jack Sends audio to an external receiver DVR VCR etc 13 MIC 6 Pin Terminal Connects to speaker microphone at...

Страница 2: ...ut which is standard for most audio applications Should a 600Ω talkback output be required please contact our factory for details regard ing instructions for switching over to 600Ω REAR OF DVR A B C 12Vdc 500mA AUDIO IN AUDIO OUT 12Vdc Power Supply AD 1 LE 242 AUDIO OUT AUDIO IN VIDEO OUT VIDEO IN AP 2TB LE 402 TLM W LE 007 Terminal Block identification of Model AP 2TB Audio Base Station A Red 12V...

Страница 3: ... AC Adapter to 120 Vac supply 2 Turn power to the unit by rotating to ON position the Power Vol ume Knob 1 The Power LED 3 will light 3 Push in to activate Zone 1 Switch 4 Zone Switch is lighted in dicating two way audio monitoring is activated Audio should be present at the Monitor Speaker 10 If there is no audio with a voltmeter check for 12 Vdc at terminals A and C Place positive lead of voltme...

Страница 4: ... MONITORING TECHNOLOGY AP 1TB AUDIO MONITORING BASE STATIONS INSTALLATION AND OPERATING INSTRUCTIONS ABOUT LOUROE ELECTRONICS Located in Van Nuys California and 32 years young Louroe Electronics has been the world leading Audio Manufacturer Our continued growth has resulted from providing innovative products receiving high customer sat isfaction maintaining strict devotion to quality standards and...

Отзывы: