26
IT
CH
GB
IE
DECLARATION OF COMPLIANCE
The installation must be done observing the norms in force particularly concerning room ventilation and discharging
gas emissions.
N.B.:
The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our sales
conditions.
TECNICAL DATA TABLE
MODEL
NOMINAL BURNER CAPACITY kW
TOT. NOM.
CAPACITY kW
Gas
coupling
ISOR7
Nr. Open ring
3,5 kW
Nr. Open ring 5,5
kW
Nr. Open ring 7,5
kW
Gas
PCD-64G
/
1
1
13
R1/2GM
PCD-68G
1
2
1
22
R1/2GM
MODEL
NOMINAL BURNER CAPACITY kW
TOT. NOM.
CAPACITY kW
Gas
coupling
ISOR7
Nr. Open ring
4 kW
Nr. Open ring
7 kW
Nr. Open ring
10 kW
Gas
PCD-84G
1
1
/
11
R1/2GM
PCD-88G
1
2
1
28
R1/2GM
INSTALLATION
•
The operations for installing, conversions for use with other types of gas and starting up must be done only by
qualified personnel whose qualifications comply with the norms in force.
•
Gas installations, the electrical connections and the rooms in which the appliances are installed must comply with
the norms in force in the Country in which the installation is carried out; above all, the appliance must be installed
in a well ventilated room, preferably under an extractor hood, so as to ensure the complete extraction of gas
emissions which are formed during combustion. The air necessary for combustion is 2m3 /h per kW of power
installed.
Insertion in metal unit and/or one made of non flammable material (Fig. A Page 2)
•
Drill a hole in the hob of the dimensions specified
•
Secure the hob in place using the purpose-provided counter brackets (B)
•
You must ensure a metal layer is fitted underneath the hob to separate the appliance from the compartment
beneath it: in this application, leave an air gap as shown in the table
•
Position the silk-screen printed control panel so that its use is facilitated using the flame adjustment-ignition
controls
•
When installation has been completed, it is advisable to check that the appliance is functioning correctly.
CHECKING FOR CORRECT VENTILATION
Make sure that the air intake into the room where the appliance is installed is sufficient for an adequate change of air, as
specified by regulations in effect.
The appliances installed in buildings open to the public must satisfy the following requirements.
Installation rules
The installation and maintenance of the appliance must be done according to the correct procedures and regulation
texts in use, particularly:
•
safety standards for the prevention of fire and panic.
Connection and installation of appliance, ventilation and exhaust removal systems, shall be done according to the
Manufacturer’s instructions and by qualified technicians and according to the regulations in effect. The electric wiring
shall conform to the regulations in effect. All fire prevention codes shall be observed.
a) General indications
(Rules valid for GB only)
- For all appliances:
Gas safety Regulations, 1984; Health and safety at Work Act, 1974 Codes of Practice, BS 8173, 1982, The Building
Regulations 1985; The Building Standards Regulations, 1981, the IEE Regulations and the by-laws of the local Water
Undertaking.