TECHNICAL DATA TABLE
MODELS
PCCD-64ET
PCCD-68ET
PCCD-84ET
PCCD-88ET
DIMENSIONS cm
400V 2N 50/60Hz 400V 3N 50/60Hz 400V 2N 50/60Hz 400V 3N 50/60Hz
POWER SUPPLY
10,9 A
21,7 A
14,78 A
29,57 A
MAXIMUM ABSORPTION
5 kW
10 kW
6,8 kW
13,6 kW
MAXIMUM POWER
4x1,5 mm²
5x2,5 mm²
4x1,5 mm²
5x2,5 mm²
POWER SUPPLY CABLE
TRANSFORMATION
POWER SUPPLY
230Vac3 50/60Hz 230Vac3 50/60Hz 230Vac3 50/60 Hz 230Vac3 50/60 Hz
MAXIMUM ABSORPTION
18,83 A
28,76 A
25,6 A
39,11 A
MAXIMUM POWER
5 kW
10 kW
6,8 kW
13,6 kW
POWER SUPPLY CABLE
4 x 2,5
mm²
4 x 4
mm²
4 x 4 mm²
4x6 mm²
POWER SUPPLY
230Vac 50/60Hz
230Vac 50/60Hz
MAXIMUM ABSORPTION
21,74 A
29,57 A
MAXIMUM POWER
5 kW
6,8 kW
POWER SUPPLY CABLE
3 x 2,5
mm²
3 x 4 mm²
INSTRUCTIONS FOR INSTALLATION
The data plate is on the back panel (see diagram in electric connection item) and has all the data necessary for the
connection.
INSTALLATION
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessibile.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishings, etc., these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
LAWS, TECHNICAL RULES AND NORMS
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription, ECI norms.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention!
In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.