Distance to inflammable material
When the fireplace insert is mounted in an existing brick fireplace, the
requirements for distance to inflammable material and fireproofing on the floor
will usually be in order.
If it is a matter of a new building, reference is made to any local regulations on
fireproofing etc. You may contact your chimney sweeper for clarification of
any issues of doubt.
Distance to inflammable material is 500mm to the side, but can be reduced to
60mm by using isolating material like “Isolrath 1000”.
For furniture, a distance of 1.1metres is recommended.
Distance to non-inflammable material
For non-inflammable material, no requirements apply.
The Chimney
A good chimney draught is essential for how well a fireplace insert will burn.
Note that there should be access to cleaning doors.
The working height of the chimney should typically range between 3.5 and 4.5
metres. Working height shall be understood as the distance from the fireplace
insert top to the top of the chimney.