Sound Advice 

 

Kindling after some lengthy pause 

If the insert has not been used for a protracted period, it should be checked 

whether the smoke ducts are intact, and whether there might be blockings in the 

chimney prior to kindling. 

 

Chimney Fire 

In the event of chimney fire, it is recommended to close the door and the 

damper, and possibly call the fire brigade. 

 

Cleaning of Fireplace Insert 

All Lotus fireplace inserts have been factory surface treated using original 

Senotherm lacquer in colours ”coke” or ”grey”. This treatment will make the 

fireplace insert exude a special smell during the initial kindlings but this will 

vanish after a few times. Provide good airing. Maintain the surface by brushing 

it, using a soft, long-haired auto brush. A cloth with water or other matter may 

not be used. 

 

Maintenance of Fireplace Insert 

It is recommended that the maintenance of your stove be performed by a 

qualified service engineer, and that only spares recommended by the 

manufacturer be used. 

 

Packings

 may look neat but they will collapse in the heat and will thus lose 

their ability to keep the fireplace insert tight. Packings should be replaced as 

required since good combustion and a clean pane will very much depend on the 

fireplace insert being tight. 

 

Skamol broken or Worn may easily be replaced as these have been mounted 

loosely, the plates are made of vermiculite this is an insulating material, and the 

material is lighter porous. 

To avoid breaking the plates, it is important that

 

wood is not thrown, but rather added into the middle of the firebox

. Should 

you get to crack a skamolplate, it has no significance for insulation. 

 

 

 

 

Содержание H570T

Страница 1: ...Assembly and User Instructions Fireplace Insert Lotus H570T Version 4 02 01 2017...

Страница 2: ......

Страница 3: ...ow run at Langeskov and exported to many European markets Lotus products are made to a fine Danish tradition serving its owners faithfully for years So once again congratulations on your new Lotus fir...

Страница 4: ...g the requirements for the assembly and the environment Also reference is made to all local regulations including those referring to national and European standards to be met in the installation of yo...

Страница 5: ...A Set screws for adjustment of the cabinet in relation to the base B Screws used for fastening the insert to the cabinet C Holes used for fastening the insert to the base...

Страница 6: ...ons are designed individually and in all cases the distance to inflammable matter must meet the values stated below The Base The base must of course be firm and have adequate load bearing capacity Thi...

Страница 7: ...e to inflammable material is 500mm to the side but can be reduced to 60mm by using isolating material like Isolrath 1000 For furniture a distance of 1 1metres is recommended Distance to non inflammabl...

Страница 8: ...rn Plate The illustration below shows how to place the smoke turn plate when viewing a section in the fireplace insert from the side The smoke turn plate is removed by lifting at one side after which...

Страница 9: ...will also have to be swept by the chimney sweeper in the years to come Using your fireplace insert Below you will find a description of kindling and firing of your fireplace insert The wood volume and...

Страница 10: ...er facing the glows Close the door tightly at once 6 The damper may be opened entirely and damped again once the fire has caught on well Just how much the damper should be opened may vary with the dra...

Страница 11: ...oft long haired auto brush A cloth with water or other matter may not be used Maintenance of Fireplace Insert It is recommended that the maintenance of your stove be performed by a qualified service e...

Страница 12: ...chloric acid or heavy metals much to the detriment of the fireplace insert and to the environment Firewood for your Lotus fireplace insert should have a diameter of 7 9 cm The essence of good combusti...

Страница 13: ...hould always be kept closed at normal operation and may be opened for kindling and firing only At normal use the surface will run hot and due care should be taken Any unauthorized change of the insert...

Страница 14: ...d directions The chimney may be too short in relation to the roof ridge or trees may have grown up generating turbulence Making your fireplace insert burn proves hard or the fire may go out This may b...

Страница 15: ...Fireplace Insert H570T...

Страница 16: ......

Страница 17: ...sing gear This warranty shall lapse if this stove is not operated so as to comply with the directions for use and if deficiencies or similar are aimed to be are remedied by a person not authorized by...

Страница 18: ...and the required manufacturing checks Johnny Ebstrup Lotus Heating Systems A S Product code Emission of CO 13 O Nominel Output kW Energy effi ciency Fire safety and Surface temperatur Release of dang...

Страница 19: ...off Energie Effizienz bei Nenn W rmeleistung 80 4 Wirkungsgrad bei Nennw rmeleistung nach Norm auf erste Dezimalstelle gerundet Hinweise zu besonderen Vorkerungen f r Zusammenbau Installation oder War...