INSTALLATION

Translation of the original instructions

8

 

Installation  operations,  any  conversion  to  other  types  of  gas  and  start-up  must  only  be
performed by qualified personnel, in accordance with current regulations.

 

Gas systems, electrical connections and premises where the appliances are installed must comply with
current regulations in the country of installation; in particular, the appliance must be installed in a room with
good ventilation, if possible under a suction hood to ensure complete evacuation of the exhaust gases
formed during combustion. The air required for combustion is 2 m3/h per kW of installed power. The
appliance can be installed alone or in series with other appliances in our production range. A minimum
distance of 10 cm between appliances must be respected to prevent contact with any walls made of
flammable material; furthermore, appropriate measures should also be adopted to ensure the thermal
insulation of flammable parts, such as the installation of heat shields; take special care to ensure that
appliances are installed in an appropriate and safe manner. The support feet can be adjustable in height and
any unevenness can therefore be eliminated.
 

GAS CONNECTION

The gas connection (see installation drawing) must be implemented using steel or copper pipes or steel
hoses, in compliance with applicable national standards. All appliances must be equipped with a gas shut-off
valve and fast-closing valve. Once installation is complete, make sure that there are no gas leaks from the
fittings; to do this, do not use a naked flame but substances that do not cause corrosion, such as solutions of
soapy water or leak detectors. All our appliances are subjected to detailed examination: the type of gas,
pressure in use and the pertinent category are indicated on the data plate (see attachment).
 

Note

 

The year of construction of the appliance is indicated under "N" on the data plate. The first 2 digits
indicate the year of construction.

 

·

THERMAL OUTPUT CONTROL

 
The appliances must be checked in order to verify that their thermal output is correct:
 

·

Thermal output is indicated on the appliance's data plate;

·

Firstly, make sure that appliance is set for the type of gas used and then make sure that the indication on

the data plate matches this gas. To adapt the appliance to another type of gas, make sure that the type of
gas in question complies with the information in this instruction manual.

 

Warning

 

Pressure is measured with a pressure gauge (minimum resolution of 0.1 mbar) mounted on
the appropriate socket. Remove the M6 locking screw and insert the pressure gauge tube.
The test must be performed with all the burners on the appliance switched on and all the
appliances in the same line switched on. After taking the measurement, replace the screw,
firmly tighten and check the seal.

 

Liquid gas connection G30 / G31
 
The liquid gas connection pressure is 30 mbar for butane and 37 mbar for propane. Check the data plate,
measure the pressure and verify that the description of the nozzle installed matches the information provided
by the manufacturer.
 
Methane gas connection H G20
 
The methane gas connection pressure is 20 mbar. Check the data plate, measure the pressure and verify
that the description of the nozzle installed matches the information provided by the manufacturer.
 

·

CHECKING THE PRIMARY AIR FOR MAIN BURNERS AND PILOT NOZZLE

Содержание FMPG-20

Страница 1: ...n and operating instructions PROFESSIONAL GAS PASTRY FRYER FPG 20 FPG 30 FMPG 20 FMPG 30 Model LIBR ISTR FPG Code 563010300 Review 1 Edition date 05 02 2020 Language English LOTUS S p A Via Calmaor 46...

Страница 2: ...ections 7 4 BURNERS TECHNICAL DATA TABLE ITGB 11 4 1 Burners technical data table 11 5 INSTRUCTIONS FOR USE 12 5 1 General information 12 5 2 Switching the pilot burner on 12 5 3 Starting the main bur...

Страница 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 FPG 20 30 A Data Plate C Gas connection...

Страница 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 FMPG 20 30 A Data Plate C Gas connection...

Страница 5: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be hel...

Страница 6: ...ginal instructions 6 2 2 Technical data table Technical data table FPG MODEL DIMENSIONS GAS FITTING ISO 7 1 RATED TOTAL GAS FLOW kW FPG 20 60x70x25h R GM 11 2 FPG 30 80x70x25h R GM 16 5 FMPG 20 60x70x...

Страница 7: ...nstall the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating m...

Страница 8: ...t do not cause corrosion such as solutions of soapy water or leak detectors All our appliances are subjected to detailed examination the type of gas pressure in use and the pertinent category are indi...

Страница 9: ...ned in a bag included in the supply and are marked in hundredths of mm see Burners technical data table INSTRUCTIONS FOR EVACUATING EXHAUST GASES A type devices see data plate A type appliances must d...

Страница 10: ...iance must be possible only by hand If the installation is under a hood the terminal part of the appliance s exhaust pipe must be at least 1 8 meters from the appliance s support surface ground The ou...

Страница 11: ...h KG G31 PROPANE 37 mbar 9 45 kWh m3st G20 METHANE H 20 mbar FPG 20 FMPG 20 Burner 11 2 kW Burner injector 1 100 mm 3 x 100 3 x 100 3 x 150 Pilot injector 30 30 51 Consumption kg h 0 875 kg h 0 875 m3...

Страница 12: ...witching off the appliance wait for a sufficient time for it to cool before carrying out any cleaning or maintenance operation Fill the tank with oil up to the lower reference mark 5 2 Switching the p...

Страница 13: ...than oil lard for example that have considerable thermal inertia it is necessary to set the thermostat to a low value e g 110 C during the first cycle not starting cold The thermostat can be set to t...

Страница 14: ...uired to have a suitable recipient for emptying the water oil Insert the drain tube as shown on the drawing position the container Push the safety device upwards against the involuntary openings A and...

Страница 15: ...ted on the component itself The appliance does not require any special maintenance but during the use of the equipment it is advisable to check the following at least once a year possibly increasing t...

Страница 16: ...le with the appropriate version and make sure that after ignition the flame correctly touches the tip of the thermocouple Warning After conversion to another type of gas update the technical data plat...

Страница 17: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...

Отзывы: