INSTALLATION
Translation of the original instructions
10
Forced evacuation (fig.4)
The gas supply to the appliance must be directly servo-controlled by the forced evacuation system and must
stop if the flow rate drops below the values indicated in point 4.3 of the UNI-CIG 8723 standard. Resetting
the gas supply to the appliance must be possible only by hand. If the installation is under a hood, the
terminal part of the appliance's exhaust pipe must be at least 1.8 meters from the appliance's support
surface (ground). The outlet section of the exhaust pipes for combustion products must be placed within the
perimeter in relation to the hood itself.
1 Windproof fume stack (fig.3) - Extractor hood (fig.4)
2 Servo system
"B11" type appliances are supplied on request with a hood or a hood and windproof fume stack to be
assembled and delivered separately.