Lotus F10T-63ETX Скачать руководство пользователя страница 15

MAINTENANCE

Translation of the original instructions

15

5 MAINTENANCE

5.1

Routine

When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation.
We therefore recommend stipulating a service contract.
 

Caution

 

Maintenance  must  only  be  performed  by  specialist  personnel  in  compliance  with  current
regulations and our own instructions.

 

Before carrying out any maintenance and/or cleaning operation:
 

·

Disconnect the appliance from the mains power supply and/or close the gas.

·

Wait for a sufficient time for the appliance to cool down.

·

Do not wash the appliance with direct or high-pressure jets of water, since any infiltration of water into the

electrical components could jeopardise correct operation of the appliance and its safety systems.

 

Warning

 

For maintenance/replacement of components, order and use only original spare parts.

 

Replacing parts must exclusively be performed by authorised and/or qualified personnel. When replacing the
electrical components of the machine and the electrical panels, scrupulously follow the technical
characteristics for the replacement component indicated on the component itself. The appliance does not
require any special maintenance but during the use of the equipment it is advisable to check the following at
least once a year (possibly increasing the frequency depending on the degree of use):
 

·

The status of connections especially on the terminal board and the power supply cable, as well as the

status of the gas connections;

·

The operating condition of the various components (perform a functional test);

·

For appliances fitted with rotary resistances, remove the hub, grease it and replace the three o-ring seals

to avoid possible leaks.

Содержание F10T-63ETX

Страница 1: ...erating instructions ELECTRIC FRYERS FOR PROFESSIONAL USE F10T 63ETX F2 10T 66ETX F13 64ETX Model LIBR ISTR FX60E POT Code 563016703 Review 1 Edition date 03 10 2019 Language English LOTUS S p A Via C...

Страница 2: ...d electronic equipment 10 2 3 Technical data table 10 3 INSTALLATION 11 3 1 Delivery checks 11 3 2 Removing the packaging 11 3 3 Mechanical installation 11 3 4 Electrical gas connections 11 4 INSTRUCT...

Страница 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 F T A Data Plate B Electrical connection...

Страница 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 F A Data Plate C Electrical connection...

Страница 5: ...ol knob to zero but the system remains operational until the problem that caused the intervention is resolved Contacts 80 and 81 are provided to enable the fryer to be controlled from a remote locatio...

Страница 6: ...tions 6 WIRING DIAGRAM D 1 Cicada 2 Switch 3 Microswitch 4 Power supply terminal board 5 Heating element 6 Resistance voltage drop 7 White indicator light 8 Red indicator light 9 Green indicator light...

Страница 7: ...INTRODUCTION Translation of the original instructions 7 Electrical technical data table MODEL WIRING DIAGRAMS F10T 63ETX D F13 64ETX D F2 10T 66ETX D D PREDISPOSITION 440V 3...

Страница 8: ...INTRODUCTION Translation of the original instructions 8 1 3 Fixing feet...

Страница 9: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be hel...

Страница 10: ...e environment and human health may be due to the misuse of the same equipment or parts of it The symbol next to the rating plate indicates the obligation of separate collection The penalties provided...

Страница 11: ...not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulat...

Страница 12: ...of it so that the device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows t...

Страница 13: ...ny cleaning or maintenance operation Fill the tank with oil up to the lower reference mark 4 2 Turning the appliance on off Turn on the switch located upstream of the appliance Turn the knob from 0 to...

Страница 14: ...e that during the emptying stage the oil does not overflow and does not represent a hazard We recommend filtering the oil every day at the end of work and changing it when necessary Turn the oil drain...

Страница 15: ...e and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personne...

Страница 16: ...g the heating element Unscrew the two 8 mm screws that fasten the bracket to the heating element and pull out the bracket until it can be removed At this point the heating element can be removed from...

Страница 17: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...