Lotus CP-94ETX Скачать руководство пользователя страница 14

INSTALLATION

Translation of the original instructions

14

Warning

 

Installation  operations,  any  conversion  to  other  types  of  gas  and  start-up  must  only  be
performed by qualified personnel, in accordance with current regulations.

 

Gas systems, electrical connections and premises where the appliances are installed must comply with
current regulations in the country of installation; in particular, the appliance must be installed in a room with
good ventilation, if possible under a suction hood to ensure complete evacuation of the exhaust gases
formed during combustion. The air required for combustion is 2 m3/h per kW of installed power. The
appliance can be installed alone or in series with other appliances in our production range. A minimum
distance of 10 cm between appliances must be respected to prevent contact with any walls made of
flammable material; furthermore, appropriate measures should also be adopted to ensure the thermal
insulation of flammable parts, such as the installation of heat shields; take special care to ensure that
appliances are installed in an appropriate and safe manner. The support feet can be adjustable in height and
any unevenness can therefore be eliminated.
 

ELECTRICAL CONNECTION

Caution

 

In accordance with international provisions, when connecting the appliance an automatic
device must be installed up-line of it so that the device can be fully disconnected from the
mains; this device must have a contact aperture of at least 3 mm.

The connection terminal is located behind the rear wall. Proceed as follows to install the power supply cable:
 

·

Remove the rear panel.

·

Pass the new connection cable through the cable gland, connect the leads to the corresponding terminal

on the terminal block and fasten them securely.

·

Lock the cable with the cable gland and refit the panel. The earth/ground lead must be longer than the

others so that if the cable gland breaks it is disconnected after the power cables.

 

Note

 

Make sure that the mains voltage complies with the data on the appliance's ID plate and that there is
good conductivity to earth/ground. Pay attention when inserting leads to ensure they do not obstruct
the normal course of work and routine appliance cleaning operations. Also make sure that the power
cable is never pulled taut and is not placed in contact with sources of heat.

Note

 

The connection cable must have the following characteristics: it must be silicone type (to
withstand temperatures of 180 °C), and must have an appropriate cross-section for the power
of the appliance (see technical data table).

 

EQUIPOTENTIAL

 
The appliance must be connected to an equipotential system. The connecting screw is located on the rear of
the appliance and is marked by the yellow symbol above it.
 

Warning

 

The manufacturer is not liable for and does not indemnify damages caused by incorrect
inadequate installations that do not comply with these instructions.

3.5

Water connection and drainage

Содержание CP-94ETX

Страница 1: ...instructions ELECTRIC PASTA COOKER FOR PROFESSIONAL USE CP 94ETX CP 98ETX CPA 94ETX CPA 98ETX Model LIBR ISTR CPX 90E CON SIC Code 563025602 Review 1 Edition date 15 01 2020 Language English LOTUS S p...

Страница 2: ...a table 12 3 INSTALLATION 13 3 1 Delivery checks 13 3 2 Removing the packaging 13 3 3 Mechanical installation 13 3 4 Electrical gas connections 13 3 5 Water connection and drainage 14 4 INSTRUCTIONS F...

Страница 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 CP 94 CP 98 A Data Plate B Electrical connection D Water connection R 3 4 M E Water drain R 1 M...

Страница 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 CPB 98E A Data Plate B Electrical connection D Water connection R 3 4 M E Water drain R 1 M...

Страница 5: ...RODUCTION Translation of the original instructions 5 1 2 Components FIG A 1 Knob 2 White indicator light 3 Green indicator light 4 Water discharge 5 Safety thermostat accessibility 6 Threaded closing...

Страница 6: ...INTRODUCTION Translation of the original instructions 6 FIG B CP Water filling tap FIG C ROTARY RESISTANCE 1 O rings 2 Rotary heating element...

Страница 7: ...nslation of the original instructions 7 WIRING DIAGRAM CP ETX A 1 Switch 2 Power supply terminal board 3 Switching terminal board 4 Heating element 5 White indicator light 6 Green indicator light 7 Sa...

Страница 8: ...control unit 2 3 Switch 4 Bipolar diverter 5 Water solenoid 6 Bipolar switch 7 Power supply terminal board 8 Switching terminal board 9 Heating element 10 Voltage drop resistance 11 Level probe 12 Whi...

Страница 9: ...INTRODUCTION Translation of the original instructions 9 Wiring diagram reference table MODELS TERMINAL BOARD CP 94ETX A CP 98ETX A A CPA 94ETX B CPA 98ETX B B...

Страница 10: ...INTRODUCTION Translation of the original instructions 10 1 3 Example installation of the appliance...

Страница 11: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be he...

Страница 12: ...electrical and electronic equipment the potential effects on the environment and human health may be due to the misuse of the same equipment or parts of it The symbol next to the rating plate indicate...

Страница 13: ...not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulat...

Страница 14: ...device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows to install the pow...

Страница 15: ...d bottlenecks or siphon effects Water is drained by gravity Inasmuch it is essential that the drain is below the exit point of the pipe Commissioning before using the appliance clean it carefully espe...

Страница 16: ...ore carrying out any cleaning or maintenance operation Do not operate the appliance without water in the tank 4 2 Turning on the appliance When the appliance is powered up the red indicator light flas...

Страница 17: ...ed nut on the front panel of the appliance and use a screwdriver to press the red button on the thermostat for a few seconds If the problem occurs again even if the tank is full of water call the assi...

Страница 18: ...tion of the device and an alarm is signalled by the red indicator light ON steady To reset the alarm condition first eliminate the fault that caused it to trip broken or disconnected level probes wate...

Страница 19: ...e and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personne...

Страница 20: ...remove the panel and remove the wires connecting the heating element Unscrew the two 8 mm screws that fasten the bracket to the heating element and pull out the bracket until it can be removed At this...

Страница 21: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...

Отзывы: