Delivery checks

On delivery, it is important to check the following:
 

·

External conditions of the packaging

·

The general status of the equipment

·

The conformity of the model with the information in the technical data plate and the instruction manual

·

The conformity of the equipment and components to the order form

 

3.2

Removing the packaging

While removing the packaging, take care not to damage the appliance. Remove the protective film from the
stainless steel and eliminate any traces of glue. Do not smoke. Perform this operation away from sources of
heat and wear protective gloves. Do not disperse packaging material in the environment, keep it out of the
reach of children and dispose in compliance with current legislation.
 

3.3

Mechanical installation

Place the appliance on a flat base. Adjust and stabilise the appliance by acting on the support feet. Make
sure that the surrounding walls and/or equipment are capable of withstanding the heat emitted by this
appliance. Connect the water supply (if necessary).
 

Caution

 

Do not install the appliance near equipment/machines used in cold processes. If the appliance
has to be installed close to cold process equipment, it is advisable to install non-combustible
thermal insulating material and/or neutral elements between them.

 

3.4

Electrical/gas connections

Before being offered for sale on the market, the appliance was subjected to gas and electrical testing (as
required). The appliance is supplied without a power cable. The installation technician must connect the
equipment in compliance with current safety regulations on the basis of the power of the appliance.

Note

 

The ID plate is located in the compartment inside the door for appliances with compartments, or on
the left side for appliances with an oven or a top. A second plate with the model and serial number is
located inside the dashboard and a third is included with the certificate of conformity. The serial
number can also be tracked from the sales document (after 2008). The plate has all the data needed
for correct electrical installation. The installation and possible conversion to another power supply
voltage (if envisaged) must be implemented exclusively by professionally qualified and authorized
personnel. Before using the appliance, carefully clean all surfaces intended to come into contact with
food.

 

Содержание CP-94ETX

Страница 1: ...instructions ELECTRIC PASTA COOKER FOR PROFESSIONAL USE CP 94ETX CP 98ETX CPA 94ETX CPA 98ETX Model LIBR ISTR CPX 90E CON SIC Code 563025602 Review 1 Edition date 15 01 2020 Language English LOTUS S p...

Страница 2: ...a table 12 3 INSTALLATION 13 3 1 Delivery checks 13 3 2 Removing the packaging 13 3 3 Mechanical installation 13 3 4 Electrical gas connections 13 3 5 Water connection and drainage 14 4 INSTRUCTIONS F...

Страница 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 CP 94 CP 98 A Data Plate B Electrical connection D Water connection R 3 4 M E Water drain R 1 M...

Страница 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 CPB 98E A Data Plate B Electrical connection D Water connection R 3 4 M E Water drain R 1 M...

Страница 5: ...RODUCTION Translation of the original instructions 5 1 2 Components FIG A 1 Knob 2 White indicator light 3 Green indicator light 4 Water discharge 5 Safety thermostat accessibility 6 Threaded closing...

Страница 6: ...INTRODUCTION Translation of the original instructions 6 FIG B CP Water filling tap FIG C ROTARY RESISTANCE 1 O rings 2 Rotary heating element...

Страница 7: ...nslation of the original instructions 7 WIRING DIAGRAM CP ETX A 1 Switch 2 Power supply terminal board 3 Switching terminal board 4 Heating element 5 White indicator light 6 Green indicator light 7 Sa...

Страница 8: ...control unit 2 3 Switch 4 Bipolar diverter 5 Water solenoid 6 Bipolar switch 7 Power supply terminal board 8 Switching terminal board 9 Heating element 10 Voltage drop resistance 11 Level probe 12 Whi...

Страница 9: ...INTRODUCTION Translation of the original instructions 9 Wiring diagram reference table MODELS TERMINAL BOARD CP 94ETX A CP 98ETX A A CPA 94ETX B CPA 98ETX B B...

Страница 10: ...INTRODUCTION Translation of the original instructions 10 1 3 Example installation of the appliance...

Страница 11: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be he...

Страница 12: ...electrical and electronic equipment the potential effects on the environment and human health may be due to the misuse of the same equipment or parts of it The symbol next to the rating plate indicate...

Страница 13: ...not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulat...

Страница 14: ...device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows to install the pow...

Страница 15: ...d bottlenecks or siphon effects Water is drained by gravity Inasmuch it is essential that the drain is below the exit point of the pipe Commissioning before using the appliance clean it carefully espe...

Страница 16: ...ore carrying out any cleaning or maintenance operation Do not operate the appliance without water in the tank 4 2 Turning on the appliance When the appliance is powered up the red indicator light flas...

Страница 17: ...ed nut on the front panel of the appliance and use a screwdriver to press the red button on the thermostat for a few seconds If the problem occurs again even if the tank is full of water call the assi...

Страница 18: ...tion of the device and an alarm is signalled by the red indicator light ON steady To reset the alarm condition first eliminate the fault that caused it to trip broken or disconnected level probes wate...

Страница 19: ...e and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personne...

Страница 20: ...remove the panel and remove the wires connecting the heating element Unscrew the two 8 mm screws that fasten the bracket to the heating element and pull out the bracket until it can be removed At this...

Страница 21: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...

Отзывы: