GENERAL INFORMATION

Translation of the original instructions

7

2 GENERAL INFORMATION

2.1

Declaration of compliance

The manufacturer declares that the appliances comply with the requirements of the regulation GAR
2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be
performed in compliance with current regulations, especially with regard to ventilation of the premises and
the exhaust gas evacuation system.
 

·

Read the warnings in this manual carefully. They provide important information about safe installation,

use and maintenance.

·

The instruction manual must be kept for the entire duration of the equipment and made available to users

for every possible consultation. The manual should be consulted for any information concerning
installation, use and maintenance of the appliance.

·

After removing the packaging, check the integrity of the equipment.

·

All packaging materials (plastic bags, polystyrene, staples, etc.) must be disposed of in compliance with

current regulations.

·

Before connecting the appliance, make sure that the information on the data plate matches the electricity

and gas mains where the appliance is installed. The manufacturer accepts no liability if the
equipment is not connected in accordance with current regulations.

·

Always keep all parts of the equipment clean to avoid the risk of oxidation/rust and/or aggression by

chemical agents.

·

The equipment must only be used by personnel trained for the purpose.

·

The installation must be implemented by professionally qualified personnel in accordance with

the manufacturer's instructions and current reference standards.

·

The electrical safety of this equipment is only ensured when it is correctly connected to an effective

ground/earth system as required by current electrical safety standards. The manufacturer cannot be held
liable for any damage caused if the system is not connected to ground/earth.

·

Before carrying out any cleaning or maintenance tasks on the equipment, unplug it from the electricity

mains. In the event of faults or malfunctions, always deactivate the appliance.

·

Repair work of any kind must only be performed by qualified personnel.

·

This appliance must only be used for its expressly intended purpose for cooking or heating food. Any

other use is considered improper.

·

The appliance is intended for professional use and must be used by trained personnel.

·

The installation and possible transformation to another power supply voltage (if envisaged), or

transformation for operation with another type of gas, must be implemented exclusively by qualified and
authorised professional personnel.

·

Before using the appliance, carefully clean all surfaces intended to come into contact with food.

·

The manufacturer declines any and all liability for any direct or indirect damage resulting from improper

use of the equipment. The manufacturer declines any and all liability for damage caused by incorrect
installation, tampering, poor maintenance and unskilled use. Moreover, the manufacturer declines any
liability for possible inaccuracies that may be contained in this booklet attributable to errors in
transcription or printing and equally reserves the right to make any changes to the product it deems
useful and/or necessary without compromising its essential characteristics.

·

The manufacturer cannot be held liable for any damage caused by failure to comply with these

basic standards and all other use and maintenance standards contained in this booklet.

Содержание 5630503A0

Страница 1: ...ation and operating instructions ELECTRICAL BAIN MARIE FOR PROFESSIONAL USE BM 114EM Model LIBR ISTR BM110E Code 5630503A0 Review 1 Edition date 16 05 2022 Language English LOTUS S p A Via Calmaor 46 31020 San Vendemiano 39 0438 778020 39 0438 778277 ...

Страница 2: ...trical and electronic equipment 8 2 3 Technical data table 8 3 INSTALLATION 9 3 1 Delivery checks 9 3 2 Removing the packaging 9 3 3 Mechanical installation 9 3 4 Electrical gas connections 9 3 5 Water connection and drainage 10 4 INSTRUCTIONS FOR USE 12 4 1 General information 12 4 2 Turning the appliance on off 12 4 3 Emptying the tank 12 4 4 Characteristics of the feed water 12 5 MAINTENANCE 14...

Страница 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG A BM A Data Plate B Electrical connection D Water connection R 1 2 M E Water drain R 1 M ...

Страница 4: ...INTRODUCTION Translation of the original instructions 4 1 2 Components FIG B CP Water filling tap FIG E 1 Water charge 2 Water drain valve ...

Страница 5: ...INTRODUCTION Translation of the original instructions 5 WIRING DIAGRAM BM 114EM 1 Switch 2 Power supply terminal board 3 Heating element 4 White indicator light 5 Green indicator light 6 Thermostat ...

Страница 6: ...INTRODUCTION Translation of the original instructions 6 1 3 Example installation of the appliance ...

Страница 7: ... electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be held liable for any damage caused if the system is not connected to ground earth Before carrying out any cleaning or maintenance tasks on the equipment unplug it from the electricity mains In the event ...

Страница 8: ...tive 2011 65 EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment the potential effects on the environment and human health may be due to the misuse of the same equipment or parts of it The symbol next to the rating plate indicates the obligation of separate collection The penalties provided for in the event of improper disposal of RAEE Waste Elec...

Страница 9: ...not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating material and or neutral elements between them 3 4 Electrical gas connections Before being offered for sale on the market the appliance was subjected to gas and electrical testing as required The a...

Страница 10: ...e device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows to install the power supply cable Remove the rear panel Pass the new connection cable through the cable gland connect the leads to the corresponding terminal on the terminal block and fasten them securely Lock the cab...

Страница 11: ...id bottlenecks or siphon effects Water is drained by gravity Inasmuch it is essential that the drain is below the exit point of the pipe Commissioning before using the appliance clean it carefully especially the tank see the cleaning and care section Check the appliance s water connection and operate it in accordance with the instructions given below Warning The appliance must only be used under s...

Страница 12: ...e water drain valve which is located in the compartment below the appliance lever in horizontal position is closed Fill the bowl with water max 60 C up to the level indicated by the symbol stamped in the bowl Turn on the switch located upstream of the appliance Turn the knob from 0 to the desired position between 30 and 90 C the white and green indicator lights will turn on The green indicator lig...

Страница 13: ...instructions 13 Pressure between 50 and 250 kPa 0 5 2 5 bar pH above 7 Electrical conductivity between 50 and 2000 μS cm 20 C Chloride ion concentration Cl not too high acceptable reference value 10ppm to avoid attacking the internal steel structures ...

Страница 14: ...ce and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personnel When replacing the electrical components of the machine and the electrical panels scrupulously follow the technical characteristics for the replacement component indicated on the component itself T...

Страница 15: ...ng all the electrical connections replace the damaged parts and install the new ones in succession HEATING ELEMENT remove the panel and remove the wires connecting the heating element From the bottom unscrew the housing that contains the heating element and once removed make the replacement Caution WHAT TO DO IN THE EVENT OF FAULTS Close the gas connection cock and or switch off the power using th...

Страница 16: ...s are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For minor cleaning a mild washing up liquid solution may also be used Do not wash the appliance with jets of water under pressure Avoid using detergents containing abrasive powders or bleaches of any kind...