![Lotus 1972 EUROPA Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/lotus/1972-europa/1972-europa_workshop-manual_1941097014.webp)
---------------------------------------------------------------------------------------- Section Updated: 2/5/2009 6:53 AM at http://www.lotus-europa.com ----------------------------------------------------------------------------------------
13
Ignition timing (static)
Non Exhaust Emission
4° B.T.D.C.
Exhaust Emission
T.D.C.
Coil
Ducellier 2765 A
Sparking plugs
- Type*
Marchal 34 HS
- Gap
.023 in. (.584 mm.)
*Alternatively, Champion N4, Champion NTY or Autolite AG22 may be used in all engines with a points gap
of .023 in. (.584 mm.).
Distributor
Type
Ducellier 4 cylinder
Drive
Skew gear from camshaft
Direction of rotation (from above)
Anti-clockwise
Contact breaker gap
.016/.019 in. (.40/.50 mm.)
Cam dwell angle
61° +- 3°
Firing angles
0°, 90°, 180°, 270° +- 1°
Centrifugal advance (Non Exhaust Emission):
Distributor
Distributor
r.p.m.
degrees B.T.D.C.
Below 550
No advance
920
7.8
1,000
8.0
2,000
13.0
3,000
18.0
Vacuum advance (Non Exhaust Emission):
Distributor
Vacuum
degrees B.T.D.C.
Hg. inches
1.5
3.937
4.6
7.874
6.5
11.811
7.0
15.748
COOLI NG SYSTEM
Type
Centrifugal pump and fan
Radiator cap relief valve
7 lbs .in .sq. (.49 kg.cm .sq .)
Thermostat nominal opening temperature
68° C.
Water pump belt tension (at longest run)
09375/.15625 in. (2.3812./3.9687 mm.)
Alternator belt tension (at longest run)
.28125/.375 in. (7.1437/9.525 mm.)