29
GB
IE
IGNITION OF THE MAIN BURNER
Ignition of the pilot burner Fig.A
Press and turn the thermostat knob (14) to position
?
. Keep pressed the knob and press repeatedly the piezo-electric button
(18). The flame ignites automatically and is visible through the inspection window in the front panel.
After ignition keep the button pressed for another 5-10 seconds, to allow the thermocouple to heat, then release.
If the flame goes out, repeat the procedure.
Ignition of the main burner and temperature regulation Fig.A
After releasing the button (14), the gas enters into the safety valve.
Turning the konb graduated fron 110 to 190 °C, the gas flows into the main burner (3) and ignites.
Turning off the main burner Fig.A
Rotate knob (14) to the
?
position. Only the pilot burner will remain lighted.
Turning off the appliance Fig.A
Pressand turn the knob (14) into position "0". This command blocks the gas flow in both the main burner and the pilot burner.
Safety thermostat
The appliance is fitted with a safety thermostat (9) which cuts off the flow of gas in the event that the temperature of the oil
bath exceeds the pre-established maximum value (230°C). The safety intervention is shown by the main burner and the pilot
burner going out.
If this occurs, it is possible to restart functioning by pushing the red button of the thermostat completely after having removed
the control panel.
If this defects occurs repeatedly, contact the assistance department which will eliminate the causes.
EMPTYING THE TUB FOR THE MOD. FQ
The user must have a container suitable for emptying the oil. This
container must be made of heat resistant material and must be made in
such a way that oil does not overflow when draining from the appliance,
thus creating a potential danger".
Insert the drain pipe according to the diagram. Position the container.
Push the safety device upwards againsts the automatic openings (A) and
press the lever (B) towards the symbol
Note:
the distance between the appliance and the corners of the support
should be taken into consideration.
Note:
The tub should be emptied when the oil is cool.
EMPTYING THE TUB FOR THE MOD. FQM
To carry out this operation you must open the drain cock which can be
reached only from the door of the cabinet underneath. Before this
operation check that the filter and the oil collector tray are in correct
position.
Note:
It is recommended to carry out such an operation when the
temperature of the oil is not very high.
INSTRUCTIONS FOR REMOVAL OF EXHAUST GASES
Type "A" Appliances (See Data Plate)
Combustion fumes from type “A” appliances must be removed by means of special hoods or similar devices which are
connected to efficient flues or stovepipes or directly to the outside (
natural removal
). Fig. 1.
If this is not possible, an extraction fan may be used if it is connected directly to the outside (
mechanical removal
). Fig.
2. The capacity of such a fan shall not be inferior to that established by regulations in effect.
Содержание FP-6G