8
Sun. Water.
Life.
BERNT LORENTZ GmbH & Co. KG
Kroegerskoppel 7, 24558 Henstedt-Ulzburg, Germany, Tel. +49 (0) 4193 7548 - 0, Fax - 29,
www.lorentz.de
All specifi cations and information are given with good intent, errors are possible and products may be subject to change without notice. Pictures may
differ from actual products depending on local market requirements and regulations.
v150106
8 4 Technical data of controller
Table 3: Technical data of PSk2 controller
Model
Solar input power
Pump motor:
rated power
Pump motor:
rated voltage
Max DC input
voltage
MPP voltage
Output current
Output frequency
[kWp]
[kW]
[V]
[V]
[V]
[A]
[Hz]
PS7k2
7
5.5
380 – 400
850
500 – 600
13
0 – 60
PS9k2
9
7.5
380 – 400
850
500 – 600
18
0 – 60
PS15k2
15
11.0
380 – 400
850
500 – 600
24
0 – 60
PS21k2
21
15.0
380 – 400
850
500 – 600
30
0 – 60
PS25k2
25
18.5
380 – 400
850
500 – 600
39
0 – 60
PS40k2
40
30
380 – 400
850
500 – 600
65
0 – 60
8 5 System layout
Figure 1: System layout
PV generator
3-phase automatic
circuit breaker
Smart PSU
fi lter cage
pressure sensor
water meter
water sensor
surface pump
valve
strainer
fi ller
valve
nonreturn valve
low water sensor
or fl oat switch
grounding rod
surge proteector
PV module
for Sun Switch
PV disconnect
PSk2 controller
fl oat switch
PV combiner