10 4 Installation and handling

Handling 

ƒ 

CS-F pumps: 

Eye bolts can be used for lifting. 

ƒ 

CS-G pumps: 

Must be lifted by the base. Use the 

eyebolts to stabilize the pump, cf. “Figure 18: Pump 
handling/lifting” below. It is recommended to use 
suitable lifting sling belts.

Strainer

 – If pipelines are welded together metal pieces 

might be present in the pipeline. Before pump instal-
lation, the inlet pipeline must be carefully cleaned. It is 
recommended to install a strainer ca. 1 m / 3 ft in front of 
the pump inlet to avoid pump damage due to any kind 
of impurities. The pressure drop of the strainer must be 
considered in the suction lift calculation, see “9.4.4 Cable 
entries and external sockets” on page 14.

Pipe system – 

We advise that pipe expansion joints are 

used close to the pump on both inlet and outlet to reduce 
noise and vibration. It is recommended that you install a 
gate valve in the suction and discharge pipeline close to 
the pump to avoid draining of the pipe while cleaning (e.g. 
filters), repairing, servicing or replacing the pump system.

WARNING – Inlet and outlet pipes 

must be mounted to the pump 
housing in a way that is free of 
tension 

CAUTION – Make sure that the 
suction pipe is sealed with no leaks, 
otherwise the pump will not prime 
or will prime insufficiently 

CAUTION – The pumps are shipped 
with plastic covers on the pump 
inlet and outlet  Remove them 
before connecting the pipes to the 

Figure 18: Pump handling/lifting

pump 

Check valve

 – A check valve at the beginning of the inlet 

pipe is needed to assure that the pump and its suction 
pipeline remains completely water filled during the time 
the pump is switched OFF. Always install a check valve with 
one inch (1”) larger diameter than the suction pipe in order 
to avoid too much suction pressure drop. For example if 
the suction pipe size is 3”, then a 4” check valve should 
be installed.

NOTE: Our experience shows that 
pressure losses of check valves are 
higher than in “Table 12: Friction 
loss for valves and fittings – equiva-
lent length of straight pipe” on 
page 31  This is probably caused 
by the screen of the check valve we 
have used in our test  We again 
strongly advise to use 1” larger 
check valve 

Содержание PSk2 CS-F Series

Страница 1: ...ll specifications and information are given with good intent errors are possible and products may be subject to change without notice Pictures may differ from actual products depending on local market...

Страница 2: ...alculating the discharge rate from the water jet 34 14 2 1 How to measure the discharge rate 34 14 2 2 How to calculate the discharge rate 34 14 2 3 Calculation example 1 34 14 2 4 Calculation example...

Страница 3: ...Figure 5 Correct controller mounting with back cover 10 Figure 6 Wrong controller mounting without back cover 10 Figure 7 Weidm ller single and double stage terminals 12 Figure 8 Weidm ller clamp cab...

Страница 4: ...installer using PumpScanner PumpScanner holds the latest versions of pump system firmware as well as new features We highly recommend you update PumpScan ner prior to each system install to ensure yo...

Страница 5: ...r the pump end and controller can be stored not used in the range of 20 C to 65 C 4 F to 149 F The components should not be exposed to direct sunlight 6 Operating Conditions Table 2 Permitted ambient...

Страница 6: ...ety directions contained in the manual existing national regulations for the prevention of accidents as well as internal guidelines and safety regulations for the operator and user must be observed at...

Страница 7: ...time according to the variation of sunlight intensity to realize the maximum power point tracking MPPT The PSk2 controller converts the DC power from the solar array to digitally created AC signal to...

Страница 8: ...or rated voltage Max DC input voltage MPP voltage Output current Output frequency kWp kW V V V A Hz PS7k2 7 5 5 380 400 850 500 600 13 0 60 PS9k2 9 7 5 380 400 850 500 600 18 0 60 PS15k2 15 11 0 380 4...

Страница 9: ...output It is safest to minimize the length of the input wiring Electronic devices are most reliable when they are pro tected from heat Mount the controller where it is shaded from the midday sun An i...

Страница 10: ...ion must be ensured by a vent or similar ventilation device Do not install in a place which is exposed to direct sunlight CAUTION The heat sink gets hot during operation Do not touch it until it has c...

Страница 11: ...should be performed by qualified experts only Unqualified handling might lead to shock burns or death WARNING The controller should only be connected to power after correct wiring or the controller mi...

Страница 12: ...erminals these are examples of the Weidm ller terminal system a ZDU 16 single stage and ZDK 2 5 double stage Strip the insulation from the end of the cable to be termi nated For a 16mm cable strip 10m...

Страница 13: ...ace pumps for submersible pumps a jumper wire is needed between 1 2 26 AWG 12 AWG 0 5 2 5mm2 2 connection to COM Pressure sensor 3 connect positive 4 20mA signal sensor supply voltage 24V load impedan...

Страница 14: ...troller housing without cutting the cable in half Exception for solar panel for SunSwitch The plug of the solar panel for SunSwitch has a red positive and a black negative cable Ensure you have the co...

Страница 15: ...you to set irradiation dependent START STOP values for the pump These settings can only be done via LORENTZ Pump Scanner Please check LORENTZ partnerNET and the PS DataModule and PumpScanner manual W...

Страница 16: ...roller must be connected to the left GND terminal The right GND terminal next to the motor phases L1 L2 L3 is for the protective earth wire of the motor 9 5 3 Insufficient ground source Where there is...

Страница 17: ...al products depending on local market requirements and regulations v150106 9 5 4 Operation with a Power Supply Unit SmartP SU WARNING Where the PSk2 controller is used in combination with a Power Supp...

Страница 18: ...extremely efficient It is impor tant to keep this efficiency throughout the entire system A main reason for loss of efficiency is pipe pressure losses Make sure that you have included the pipe pressu...

Страница 19: ...nding resistance 1 Set the multimeter to resistance measurement and select the lowest measuring range 2 All PSk2 motors are 3 phase motors Measure the resistance of phase to phase L1 L2 L2 L3 L3 L1 Ma...

Страница 20: ...tlet to reduce noise and vibration It is recommended that you install a gate valve in the suction and discharge pipeline close to the pump to avoid draining of the pipe while cleaning e g filters repa...

Страница 21: ...10 0 1 G1 34 0 1 20 0 2 2 0 1 17 0 1 30 0 2 2x45 1 5x45 0 3 0 1 0 3 Figure 19 Technical drawing of adaptor in mm Figure 20 Adaptor welded on inlet pipeline Figure 21 Mounted probe housing Figure 22 M...

Страница 22: ...Figure 23 HDPE pipe tee piece Figure 24 steel steel flange with adaptor in HDPE pipe 1 female thread Whitworth pipe thread for the sensor housing HDPE pipe adaptor steel stainless steel pipe pipe diam...

Страница 23: ...ill stop the pump The TANK FULL indicator on the controller will light up When the water level drops the float switch will signal the controller The indicator light will go out and the pump will resta...

Страница 24: ...sically installing the pump make sure to setup the parameters correctly using PumpScanner Depending on the pump system up to 30 more water can be pumped by configuring the 11 1 Filling pump with water...

Страница 25: ...connection present INDICATOR LIGHTS SYSTEM green The controller is switched on and the power source is present In low power conditions the light may show even if there is not enough power to run the p...

Страница 26: ...d that all connections have been double checked for correct connection 2 Connect the power to the PSk2 controller but the ON OFF toggle switch of the PSk2 controller is in position OFF The pump must n...

Страница 27: ...t switch resets 2 to 3 seconds 3 After low water probe regains contact with water in the source 15 minutes but the indicator light will slowly flash for the rest of the solar day or until power is dis...

Страница 28: ...ter to test the control circuit 6 When conducting any insulation test on the motor you must dismantle the connection between motor and controller Main points for inspection and maintenance Please use...

Страница 29: ...e Figure 30 Schematic view of an open pump system 15 1 2 Inlet suction pipeline The target is to reduce the inlet pressure losses to a minimum In order to achieve maximum suction lift and reduce the r...

Страница 30: ...87 40 104 7 4 0 75 2 48 50 122 12 3 1 25 4 11 Table 10 Friction loss in Schedule 40 steel pipe with Standard Inside Diameter SIDR Flowrate Q 2 2 1 2 3 3 1 2 4 5 6 SIDR SIDR SIDR SIDR SIDR SIDR SIDR US...

Страница 31: ...t m ft m ft m ft m 90 normal elbow 2 7 0 8 3 5 1 1 4 3 1 3 5 5 1 7 6 5 2 0 8 0 2 4 10 1 3 1 45 elbow 1 3 0 4 1 7 0 5 2 0 0 6 2 5 0 8 3 0 0 9 3 8 1 2 5 4 1 6 90 long radius elbow 1 7 0 5 2 3 0 7 2 7 0...

Страница 32: ...pe 100 lpipe lelbow lvalve The friction losses of the fitting and the valve can be read off from Table 12 Friction loss for valves and fittings equivalent length of straight pipe on page 31 as equival...

Страница 33: ...nation of the friction losses Hf Hf pipe 100 lpipe lelbow lvalve The friction losses of the fitting and the valve can be read off from Table 12 Friction loss for valves and fittings equivalent length...

Страница 34: ...the other leg is adjusted to 4 at the water jet surface NOTE The pipe s wall thickness is ignored The measure result depends on the measuring precision Figure 33 Reading off the discharge rate accordi...

Страница 35: ...85 19 146 33 228 52 334 76 8 20 11 3 20 5 27 6 44 10 63 14 98 22 166 38 260 59 380 86 9 23 13 3 22 5 32 7 50 11 70 16 110 25 187 42 293 67 430 98 10 25 14 3 25 6 33 8 56 13 78 18 122 28 208 47 326 74...

Страница 36: ...Water detection sensor installed yes Low water sensor installed yes SunSwitch installed yes Pressure sensor installed yes Other accessories PV generator PV module brand PV module model Number of pane...

Отзывы: