3DM
®
-GX5-35
DCP Manual
5.1.4
Scaled Ambient Pressure (0x80, 0x17)
Description
Scaled Ambient Vector
Notes
This is a scalar which gives the instantaneous ambient pressure reading. This quant-
ity is fully temperature compensated and scaled into units of milliBar.
Field Format
Field Length
Data
Descriptor
Message Data
06 (0x06)
0x17
Binary
Offset
Description
Data Type
Units
0
Ambient
Pressure
float
milliBar
5.1.5
Delta Theta Vector (0x80, 0x07)
Description
Time integral of angular rate.
Notes
This is a vector which gives the time integral of angular rate over the interval set by
the IMU message format command. It is expressed in terms of the 3DM-GX5-35’s
local coordinate system in units of radians.
Field Format
Field Length
Data
Descriptor
Message Data
14 (0x0E)
0x07
Binary
Offset
Description
Data Type
Units
0
X Delta Theta
float
radians
4
Y Delta Theta
float
radians
8
Z Delta Theta
float
radians
72